Panasonic KX-TDA50 Installation Manual page 150

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

4.1 Troubleshooting
Error
Error Message
Code
325
IP-GW LAN Chip
Failure
326
IP-GW Stop
370
IP-GW Rebooted
by Maintenance
Console
371
IP-GW Rebooted •
391
Data Link
established
392
Clock master card
selected
393
LAN Carrier
detected
394
IP-GW Core Data
Link established
395
IP-GW
Gatekeeper Error
Cleared
396
IP-GW Run
510*
SMDR disconnect •
150
Installation Manual
PROBABLE CAUSE
Detection of IP-GW
LAN Chip failure
IP-GW is stopped from
remote maintenance
PC
IP-GW is rebooted
from a remote
maintenance PC
Optional service card
malfunction: IP-GW
Connection with PC
Phone/PC Console or
Voice Processing
System (DPT
Integration)
established or restored
Clock master card has
been changed to the
one indicated by the
sub code
IP-GW card connected
to the LAN
IP-GW Core Data Link
established
Connection to the
Gatekeeper is
recovered
IP-GW is started from
remote maintenance
PC
RS-232C cable not
connected
Breaking of RS-232C
cable
Printer (terminal
equipment)
malfunction
SOLUTION
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the Installation Manual for IP-GW card)
This information is logged when IP-GW
is stopped from remote maintenance
PC
This information is logged when IP-GW
is rebooted from a remote maintenance
PC
Check whether the software version of
the IP-GW card is correct
Replace the corresponding optional
service card
This information is logged when
connection with PC Phone/PC Console
or Voice Processing System (DPT
Integration) is established, and does
not indicate an error condition that
needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.
Check if the proper card is selected as
the new clock master card
This information is logged when
synchronization of LAN is established
This information is logged when IP-GW
Core Data Link is recovered
This information is logged when
connection to the Gatekeeper is
recovered
This information is logged when IP-GW
is started from remote maintenance PC
Check the RS-232C cable
Check the terminal equipment

Hide quick links: