Intel Light Guided Diagnostics; 5-Volt Stand-By Led; Fan Fault Led; Cpu Fault Led - Intel S2600IP Technical Product Specification

Server and workstation board
Hide thumbs Also See for S2600IP:
Table of Contents

Advertisement

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSIntel® Light Guided Diagnostics
®
8.
Intel
Light Guided Diagnostics
Both server boards have several onboard diagnostic LEDs to assist in troubleshooting board-
level issues. This section provides a description of the location and function of each LED on the
server boards.
8.1

5-volt Stand-by LED

Several server management features of these server boards require a 5-V stand-by voltage
supplied from the power supply. The features and components that require this voltage must be
present when the system is "power-down". The LED is illuminated when AC power is applied to
the platform and 5-V stand-by voltage is supplied to the server board by the power supply.
8.2

Fan Fault LED

Fan fault LEDs are present for the two CPU fans and the one rear system fan. The fan fault
LEDs illuminate when the corresponding fan has fault.
8.3

CPU Fault LED

CPU fault LED should correspond to the socket with the failed or disabled CPU. The CPU LEDs
illuminate when CPU failure or Disable.
Revision 1.1
Intel order number G34153-003
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W2600crS2600ip

Table of Contents