Platform Management OverviewIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
The sensor is rearmed on power-on (AC or DC power on transitions).
IPMI Sensor Characteristics
1. Event reading type code: 03h (Digital discrete)
2. Sensor type code:
3. Rearm type:
The following sensor-specific offsets are supported:
Offset
01h
4.4
Thermal and Acoustic Management
®
The Intel
Server Board S2600IP and Intel
thermal and acoustic management features to maintain comprehensive thermal protection as
well as intelligent fan speed control. The features can be adjusted in BIOS interface with path
BIOS > Advanced > System Acoustic and Performance Configuration.
4.4.1 Set Throttling Mode
Select the most appropriate memory thermal throttling mechanism for memory sub-system from
[Auto], [DCLTT], [SCLTT] and [SOLTT].
[Auto] – BIOS automatically detect and identify the appropriate thermal throttling mechanism
based on DIMM type, airflow input, DIMM sensor availability.
[DCLTT] – Dynamic Closed Loop Thermal Throttling: for the SOD DIMM with system airflow
input
[SCLTT] – Static Close Loop Thermal Throttling: for the SOD DIMM without system airflow
input
[SOLTT] – Static Open Loop Thermal Throttling: for the DIMMs without sensor on dimm
(SOD)
The default setting is [Auto].
4.4.2 Altitude
Select the proper altitude that the system is distributed from [300m or less], [301m-900m],
[901m-1500m], [Above 1500m] options. Lower altitude selection can lead to potential thermal
risk. And higher altitude selection provides better cooling but with undesired acoustic and fan
power consumption. If the altitude is known, higher altitude is recommended in order to provide
sufficient cooling. The default setting is [301m – 900m].
4.4.3 Set Fan Profile
[ Performance] and [Acoustic] fan profiles are available to select. The Acoustic mode offers best
acoustic experience and appropriate cooling capability covering mainstream and majority of the
add-in cards. Performance mode is designed to provide sufficient cooling capability covering all
kinds of add-in cards on the market. The default setting is [Performance]
60
07h (Processor)
Manual
Table 19. Support MSID Mismatch Sensor Offsets
Description
State asserted
®
Workstation Board W2600CR offers multiple
Intel order number G34153-003
Event Logging
Assertion and deassertion
Revision 1.1