Mounting
The HDMI DA units can be mounted in any of the following locations:
•
•
•
Desktop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in any convenient
location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of
these products in a rack:
1.
2.
3.
4.
5.
Rack Mounting Procedure
See the HDMI DA Series product page at
kits and shelf accessories. Follow the instructions provided with the shelf accessories.
Under-desk Mounting
See the HDMI DA Series product page at
mounting kits. Follow the instructions provided with the kit.
Desktop Placement
Rack Mounting
Under-desk Mounting
Elevated operating ambient temperature — If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C)
specified by Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Consider the equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections to
the branch circuit (such as the use of power strips).
www.extron.com
for a list of suitable rack mounting
www.extron.com
for a list of suitable under-desk
HDMI DA Series • Mounting
16
Need help?
Do you have a question about the HDMI DA Series and is the answer not in the manual?
Questions and answers