MESSAGE
*
* Note: This message can also appear if the pump has not regained
prime after the hot tub has been drained and refilled. If you suspect that
this is the case, see the instructions on page 77 under "pump does not
operate and icon does".
Note: This error commonly occurs when the hot tub is first filled because
tap water is often very cold.
MEANING
WARNING: RISk OF HYPERTHERMIA
!
(OVER-HEATING) CAUSING SEVERE
INjURY, BURNS, OR WELTS.
Overheat Protection (Heater is deactivated, filter/
circulation pump is activated). Water temperature
is above acceptable limits. dO NOT ENTER THE
WATER! Remove hot tub cover to speed cooling.
See "Water is too hot" (page 78). If condition
persists, contact your Sundance Spas dealer or
qualified service technician.
If the hot tub water is more than -7°C cooler than the
temperature setpoint, jets pump #1 and heater will
automatically activate to provide freeze protection.
The hot tub will stay in this mode until the water
temperature reaches 15 degrees below the set
temperature. No corrective action is necessary.
FLOW SWITCH (Heater is deactivated. The filter/
circulation may also be deactivated). Proper flow of
water is inhibited or a flow switch has malfunctioned.
Check for proper water level and for clogged filter
(pages 61-62). Contact your Sundance Spas dealer
or qualified service technician.
Circuit board temperature has exceeded acceptable
limit. This message will disappear when the circuit
board temperature drops below acceptable limit. If
condition persists, provide shade for equipment side
of hot tub.
FREEZE PROTECTION
A potential freeze condition has been detected. No
action is required. Jets pump(s) operate until the hot
tub is out of danger.