FUNCTIONAL SPECIFICATIONS
ADF Transmission
Quick Memory Transmis-
sion
Memory Transmission
(18)
Forwarding transmission .............................. Yes
(19)
Interruption transmission............................... Single station transmission reservation automatically
(20)
International
communication............................................. Yes
(21)
V34-off transmission .................................... Transmitted without V34 mode. The V34-off appoint-
(22)
Long original transmission ............................ No
(23)
ADF irregular-size transmission ..................... Possible to transmit irregular-size originals from ADF.
(24)
Restored transmission .................................. No
(25)
Instant batch transmission
(Bundled transmission) ................... No
(26)
Confidential transmission .............................. Transmission to the confidential BOX of a remote sta-
1-8
Mixture of ADF/Platen
Platen Transmission
Documents
One page only
X
After the Separate Scan
After the Separate Scan
setting, the setting is read
setting, the setting is read
with the [Start] key and
with the [Start] key and
the communication is
the communication is
started up with the [Fin-
started up with the [Fin-
ish] key.
ish] key.
X
interrupts between stations of multiple station commu-
nications.
ment can be registered in the abbreviated / program
dials. This is used when the transmission error code
related to V34 occurs frequently.
The main scanning is the max. document width set on
ADF, and the sub scanning depends on document
length. The maximum is 432 mm/17 inches.
tion by using the F code (SUB/SID). Appoints the con-
fidential BOX No. by using SUB. Possible to select the
SID sending Yes / No on the control panel.
FK-502 Service Manual Ver.1.0
When the FAX memory is full, automatically
switched to the quick memory transmission.
Advanced Communica-
Manual Transmission
tion Function
(Only the communication
mode is possible)
Yes
No
Partly Yes
Automatic forward: Automatic forward of received
documents to remote stations registered in
advance.
Manual forward: No
When the remote station is V17, communications
start at TCM 7,200bps. When the remote station is
V34, they start at 28,800bps.
Transmission When the
Printer is Active
X
X

Hide quick links:

Advertisement

Table of Contents
loading