FK-502 Service Manual Ver.1.0
Parameter
V8 / V34 Proto-
col
V17 EP TONE
V29 EP TONE
Protocol
V17 Selection
Mode "-"
ANSam Send
Time
Foreign Com-
munication
Function
No. of DIS Wait-
ing Times at
Foreign Com-
munication
Int'l
Comm.
Function
V34 Speed
V17 Speed
V29 Speed
T1
DCS-TCF
DELAY
TIMER 1
CED-DIS
DELAY
PIX-PMC
DELAY
Set Value
ON / OFF
ON / OFF
ON / OFF
ON / OFF
1.0 to 5.5[sec]
(Set the value in steps of
0.5ms.)
ON / OFF
1,2[times]
33600 to 16800[bps]
(in steps of 2400)
14400 to 7200[bps]
(in steps of 2400)
9600 to 2400[bps]
(in steps of 2400)
30 to 90[second]
(Set the value in steps of 5s.)
50 to 150[ms]
(Set the value in steps of
10ms.)
50 to 150[ms]
(Set the value in steps of
10ms.)
50 to 150[ms]
(Set the value in steps of
10ms.)
FUNCTION PARAMETER SETTING
Factory-
shipped
Reference
Default
Setting
ON
ON
Yes
OFF
Yes
OFF
Yes
4.0[sec]
Yes
ON
Yes
1[time]
28800[bps]
7200[bps]
4800[bps]
35[sec]
Yes
80[ms]
Yes
80[ms]
Yes
80[ms]
Yes
3-11