Konica Minolta FK-502 Service Manual page 171

Hide thumbs Also See for FK-502:
Table of Contents

Advertisement

Setting
Address
---
0e00a5
JBIG parameter
---
0e00a6 - 0e00a9 JBIG LO size
---
0e00aa
(Inhibit of) JBIG off Rx-Function ON/OFF
---
0e00ab
JBIG off Rx-JBIG off time after error
---
0e00ac
PBX dial tone detection frequency upper limits
---
0e00ad
PBX dial tone detection frequency lower limits
---
0e00ae
PBX dial tone tone detection time
---
0e00af
PBX dial tone ON time min. value
---
0e00b0
PBX dial tone OFF time max. value
---
0e00b1
PBX dial tone OFF time min. value
---
0e00b2
PBX dial tone tone waiting time
---
0e00b3
PBX dial tone instantaneous break detection time
---
0e00b4
PBX dial tone frequency synchronization parameter (HEX)
---
0e00b5
1st dial tone detection frequency upper limits
---
0e00b6
1st dial tone detection frequency lower limits
---
0e00b7
1st dial tone tone detection time
---
0e00b8
1st dial tone ON time min. value
---
0e00b9
1st dial tone OFF time max. value
---
0e00ba
1st dial tone OFF time min. value
---
0e00bb
1st dial tone tone waiting time
Item
bit7
bit6
JBIG optional LO size used for reduction (HEX) (setting range:0x01to0xffffffff)
[0] = HH, [1] = HL, [2] = LH, [3] = LL
Timer value after JBIG reception error to reset JBIG off reception (min, HEX)(10 min. if 0)
PBX dial tone detection frequency upper limit (unit: 10 Hz, HEX)
PBX dial tone detection frequency lower limit (unit: 10 Hz, HEX)
PBX dial tone detection time or max. ON time value (unit: 20 ms, HEX)
PBX dial tone ON time min. value (unit: 20ms, HEX)
PBX dial tone OFF time max. value (unit: 20 ms, HEX)
PBX dial tone OFF time min. value (unit: 20 ms, HEX)
PBX dial tone waiting time or pre-pause time (unit: 1 sec, HEX)
Instantaneous shutdown time (unit: 20 ms, HEX) or tone detection frequency (times, HEX)
1st dial tone detection frequency upper limit (unit: 10 Hz, HEX)
1st dial tone detection frequency lower limit (unit: 10 Hz, HEX)
1st dial tone detection time or ON time max. value (unit: 20 ms, HEX)
1st dial tone ON time min. value (unit: 20 ms, HEX)
1st dial tone OFF time max. value (unit: 20 ms, HEX)
1st dial tone OFF time min. value (unit: 20 ms, HEX)
1st dial tone waiting time or pre-pause time (unit: 1 sec, HEX)
Contents
bit5
bit4
bit3
bit2
Default
North Amer-
bit1
bit0
Japan
FP JBIG of
JBIG optional L0
optional LO size is
function
used for reduction
0x01
0: No
0: No
1: Yes
1: Yes
0x00
0x00
0x00
0x80
JBIG off function
at A3 high-defini-
JBIG off function
tion reception
after JBIG recep-
(DIS re-transmis-
tion error
0x00
sion)
0: Enable
0:OFF
1: Disable
1:ON
0x0a
0x31
0x1f
0x32
0x00
0x00
0x00
0x03
0x00
0x03
0x31
0x1f
0x32
0x00
0x00
0x00
0x03
Europe
ica
0x01
0x01
0x00
0x00
0x00
0x00
0x00
0x00
0x80
0x80
0x00
0x00
0x0a
0x0a
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x03
0x03
0x00
0x00
0x03
0x03
0x35
0x00
0x23
0x00
0x32
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x03
0x04

Hide quick links: