Troubleshooting the Drive
200–400 HP Drives (with the motor connected)
Meter
IGBT
Connection
No.
(+)
(-)
All
U/T3
*
IGBTs
*
U/T3
tested in
U/T3
**
parallel
*
U/T3
* (+) DC Bus power terminal
** (-) DC Bus power terminal
200–400 HP Drives (with the motor disconnected)
Meter
IGBT
Connection
No.
(+)
(-)
1
*
W/T1
2
*
V/T2
3
*
U/T3
4
W/T1 **
5
V/T2 **
6
U/T3
**
* (+) DC Bus power terminal
** (-) DC Bus power terminal
Table 9.1 - Resistance Checks (Continued)
Component is OK if
resistance (R) is:
10 < R < 1 Megohm
Component is OK if
resistance (R) is:
10 < R < 1 Megohm
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity
9-11