Table 9.1 - Resistance Checks - Reliance electric GV3000 Instructions Manual

Ac drive
Table of Contents

Advertisement

Troubleshooting the Drive
Input
Meter
Diode
Connection
No.
(+)
(-)
1
*
R/L1
2
*
S/L2
3
*
T/L3
4
R/L1
**
5
S/L2
**
6
T/L3
**
* (+) DC Bus Volts power terminal
** (-) DC Bus Volts power terminal
Input
Meter
Diode
Connection
No.
(+)
(-)
1
47
1L1
2
47
1L2
3
47
1L3
4
1L1
45
5
1L2
45
6
1L3
45
Input
Meter
Diode
Connection
No.
(+)
(-)
1
47
1L1
2
47
1L2
3
47
1L3
4
1L1
45
5
1L2
45
6
1L3
45
Table 9.1 – Resistance Checks
1–60 HP Drives
Component is OK if
resistance (R) is:
50K < R < 10 Megohms
60–100 HP Drives
Component is OK if
resistance (R) is:
0.3 kohm < R < 8 kohm
100–150 HP Drives
Component is OK if
resistance (R) is:
R > 100 kohm
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity
Component is defective if:
Continuity (short circuit)
9-9