Table 3.10 – Recommended Motor Lead Lengths for Reliance Inverter Duty Motors
GV3000/SE
HP Rating
Filter Type
1 to 2
3 to 5
7.5 to 10
15 to 20
25 to 60
75 to 100
125 to 150
200 to 400
1 to 2
3 to 5
7.5 to 10
15 to 20
A 5% reactor/filter
at the drive.
25 to 60
75 to 100
125 to 150
200 to 400
GV3000/SE
480 Volt
HP Rating
5% Reactor
1
RL-00202
2
RL-00403
3
RL-00403
5
RL-00803
7.5
RL-01203
10
RL-01803
15
RL-02503
20
RL-03503
25
RL-03503
30
RL-04503
40
RL-05503
Standard reactors can be used on GV3000/SE drives with carrier frequency settings up to 8 kHz.
All reactors listed are UL-recognized (UL-506 File #E53094) and CSA certified (CSA File #LR29753).
Maximum Lead Length in Feet with
2 kHz
500
500
750
800
None
800
800
800
1000
1000
1000
1000
1000
1000
1000
1000
1000
Table 3.11 – Compatible Reactors
GV3000/SE
HP Rating
100
125
150
200
250
300
350
400
GV3000/SE AC Drive Hardware Reference, Version 6.06
460 VAC Motor
Carrier Frequency
4 kHz
8 kHz
500
500
500
500
500
500
500
500
500
500
500
500
500
500
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
480 Volt
5% Reactor
50
RL-08003
60
RL-08003
75
RL-10003
RL-13003
RL-16003
RL-20003
RL-25003
RL-32003
RL-40003
RL-50003
RL-50003