Technical Specifications
Table A.6 – Encoder Feedback Device Specifications (FVC Regulation Only)
Specification
Motor Poles
Overcurrent IET
Overload Current Rating
Speed Control Range
Speed Control Response
Encoder Feedback
Service Factor
)
Table A.7 – Input Signal Response Times (Maximum)
Signal Type and Source
Keypad START
Terminal Strip:
START
STOP, RESET, FL
Preset Speeds
Analog Speed/Trim
Reference
Analog Torque
Reference
Network:
START
STOP, RESET, FL
Analog Speed/Trim
Reference
Torque Reference
*These are the maximum times from transitioning the input to the drive reacting to the input.
2, 4, 6, or 8 poles
200% load (based on drive nameplate
rating)
150% for 1 minute (based on drive
nameplate rating)
1:600 with 1024 PPR
15 Hz (typical)
15 V differential quadrature, encoder
incremental (512 PPR, 1024 PPR, 2048
PPR, 4096 PPR)
1.0
Volts/Hertz Regulation*
150 milliseconds
126 milliseconds
75 milliseconds
75 milliseconds
16 milliseconds
N/A
46 milliseconds + network
transport time
26 milliseconds + network
transport time
5 milliseconds +
network transport time
N/A
Rating
Vector Regulation*
130 milliseconds
105 milliseconds
75 milliseconds
75 milliseconds
5 milliseconds
0.5 milliseconds
25 milliseconds + network
transport time
25 milliseconds + network
transport time
5 milliseconds +
network transport time
0.5 milliseconds +network
transport time
A-3