9-10
Input
Meter
Diode
Connection
No.
(+)
(-)
1
*
R/L1
2
*
S/L2
3
*
T/L3
4
R/L1
**
5
S/L2
**
6
T/L3
**
* (+) DC Bus power terminal
** (-) DC Bus power terminal
Meter
IGBT
Connection
No.
(+)
(-)
1
*
W/T3
2
*
V/T2
3
*
U/T1
4
W/T3
**
5
V/T2
**
6
U/T1
**
* (+) DC Bus Volts power terminal
** (-) DC Bus Volts power terminal
Meter
IGBT
Connection
No.
(+)
(-)
1
47
W
2
47
V
3
47
U
4
W
45
5
V
45
6
U
45
Table 9.1 - Resistance Checks (Continued)
200–400 HP Drives
Component is OK if
resistance (R) is:
R > 100 kohm
1–60 HP Drives
Component is OK if
resistance (R) is:
50K < R < 10 Megohm
60–150 HP Drives
Component is OK if
resistance (R) is:
0.3 kohm < R < 8 kohm
GV3000/SE AC Drive Hardware Reference, Version 6.06
Component is defective if:
Continuity (short circuit)
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity