Inlet/Drain Led Flashes During Water Intake, Dishwasher Ends Selected Program. (F12, F13 Or F19) - Miele G1000 Technical Information

Miele dishwashers technical information
Table of Contents

Advertisement

G1000 / G2000 Dishwashers
5. With the non-return valve removed, check the drain pump for proper operation
by performing the following steps:
a. Check the Drain pump Impeller blades for proper rotation. If stuck, look for
b. Remove the lower service door panel.
c. Operate the dishwasher in a draining step.
d. Check for power at the Drain pump. If pump is receiving power,
6. Drain hose kinked.
a. Replace Drain hose
7. Check the heater pressure switch and insure the contacts are in the correct
position after drain. replace if necessary.
6.8.14
Inlet/Drain LED Flashes During Water Intake, Dishwasher ends selected
program. (F12, F13 or F19)
1. Check if On-site water supply valve is closed.
a. Open the water supply valve
2. Check if On-site water supply has low water pressure, less than 14.5 psi.
a. The on-site water supply should be checked by a specialist.
3. Check the WPS (WaterProof System) valve Filter for blockage by performing the
following steps:
a. Disconnect the dishwasher from the power supply.
b. Close the water supply valve.
c. Unscrew the WaterProof System from the water supply valve.
d. Remove the washer from the threaded union.
e. Remove the filter with needle nose pliers.
f.
4. Check Water inlet valve for proper operation by performing the following steps:
a. Insure water supply is open and there is access to the valve housing.
b. Select a wash program and start.
c. After the drain step (30 sec.) the water inlet step will begin. Hold
d. Remove bottom drip pan and check the electrical connector to the
e. Check for power coming off the electronic board. If no power,
Foreign objects blocking Impeller blades and remove. If Impeller blades are
jammed and no foreign objects are located, proceed to next step.
Clean or replace the filter as necessary.
you hand around the valve housing. If you feel a mild vibration,
then the valve is receiving power. Replace the WPS valve (Y2). If
not go to the next step.
inlet valves mounted on the left plinth for power. If power is
available troubleshoot connector and wiring accordingly. If not go
to the next step.
replace the electronic board. If power is present, check wiring from
electronic board to electrical connector. Replace and repair as
necessary.