G1000 / G2000 Dishwashers
Technical Information
(miniprogram):
This starts with 30 sec. drainage, which begins with pulsed priming
(2 sec. on / 2 sec. off). The water inlet valve is then activated (on
models with and without slide shutter) until 5.4 l has been taken in. At the same
time the water inlet valve is activated, the slide shutter is set to the middle
spray arm position. The circulation pump with switched auxiliary winding is then
operated. After 2 sec. the slide shutter is set to the top/bottom spray arm
position. If a spray arm fault is registered during circulation pump operation, the
pump is switched off after 60 sec., otherwise it operates for a further 120 sec.
202