2. Place a screwdriver on the retaining clip spring, Fig. 5-34, and press against it.
3. Turn the handle clockwise and release the filter combination clip connection.
5.4.21

Filter Combination Assembly (New Micro Fine Filter and Handle)

Note
During assembly, the dishwasher is used as a guide.
If a new micro fine filter and handle (crown coarse filter) are used, a
locking piece is not required.
1. Place the micro fine filter in the sump. Ensure that the lug is positioned towards
the rear of the machine.
Figure 5-35: Micro Fine Filter Installation
2. Turn the micro fine filter clockwise as far as possible, Fig. 5-35.
3. Place the large surface area fine filter in position.
G1000 / G2000 Dishwashers
100