Auxiliary Port Input Communications
F9 Search back for "xx" character from current cursor position, leaving cursor
pointing to "xx" character. Syntax = F9xx (xx stands for the hex value for an
ASCII code, see Hex to ASCII Conversion chart, page 3-20.)
E6 Search ahead for the first non "xx" character from the current cursor posi-
tion, leaving cursor pointing to non "xx" character. Syntax = E6xx (xx
stands for the hex value for an ASCII code, see Decimal to Hex to ASCII
Conversion chart, page 3-20.)
E7 Search back for the last instance of "xx" character from the current cursor
position, then increment cursor. Syntax = E7xx (xx stands for the hex value
for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.)

Miscellaneous Commands

FB Suppress all occurrences of up to 15 different characters, starting at the cur-
rent cursor position, as the cursor is advanced by other commands. When
the FC command is encountered, the suppress function is terminated. The
cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where
nn is a count of the number suppress characters in the list and xxyy .. zz is
the list of characters to be suppressed. (xx stands for the hex value for an
ASCII code, see Hex to ASCII Conversion chart, page 3-20.)
FC Disable suppress filter and clear all suppressed characters. Syntax = FC.
E4 Replaces up to 15 characters in the data string with user specified charac-
ters. Replacement continues until the E5 command is encountered. Syntax
= E4nnxx
xx
1
to be replaced plus replacement characters; xx
replaced and xx
and zz
.
2
E5 Terminates character replacement. Syntax = E5.
FE Compare character in current cursor position to the character "xx." If charac-
ters are equal, increment cursor. If characters are not equal, no format
match. Syntax = FExx (xx stands for the hex value for an ASCII code, see
Hex to ASCII Conversion chart, page 3-20.)
EC Check to make sure there is a numeric character at the current cursor posi-
tion. If character is not numeric, format is aborted. Syntax = EC.
ED Check to make sure there is a non-numeric character at the current cursor
position. If character is numeric, format is aborted. Syntax = ED.
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5). Syntax =
EFnn where nn is a count of the number 5 ms delays, up to 9,999.
3 - 26
yy
yy
...zz
zz
2
1
2
1
2
defines replacement characters, continuing through zz
2
where nn is the total count of both characters
defines characters to be
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imageteam 3870Imageteam 3875Scanteam 5770

Table of Contents