Summary of Contents for Hand Held Products Valueteam 3060
Page 2
Disclaimer Hand Held Products, Inc. d/b/a HHP (“HHP”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should, in all cases, consult HHP to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HHP.
The CE mark on the product indicates that the system has been tested to and conforms with the provisions noted within the 89/336/ EEC Electromagnetic Compatibility Directive, EN55022:1998 Class A. For further information please contact: Hand Held Products, Inc. Nijverheidsweg 9 5627 BT Eindhoven The Netherlands...
Table of Contents Chapter 1 Getting Started About This Manual Chapter 2 Terminal Interfaces Keyboard Wedge Interface RS-232 Serial Interface USB Keyboard Interface Chapter 3 Programming the Scanner HHP SET ™ Data Editor Bar Code Programming Menu Programming Procedures Host Interface Selection...
The IMAGETEAM™ 3220 Mid-Range Linear Imager replaces traditional laser bar code scanners with a high speed scanner at a lower cost. Equipped with a new generation light intensifier and optical design, the IT3220 has a high intensity aiming line and captures bar codes from as far away as 8 inches (20.3 cm).
Page 8
S/N : A1210001 S/N : A1210001 N344 N344 Made in Taiwan Made in Taiwan Product Label Product Label Hand Held Products, I nc. Hand Held Products, I nc. Hand Held Products, I nc. www.hhp.com www.hhp.com www.hhp.com N344 N344 Made in Taiwan...
Page 9
To use the HHP SET with the IT3220, the user must have a serial adapter cable and a power supply. Please refer to Chapter 3 “Programming the Scanner” to understand all details of HHP SET. You will find HHP SET has totally changed the traditional ways of managing your bar code reading device.
Terminal Interfaces Keyboard Wedge Interface The keyboard wedge interface allows data transmission from the scanner to the host through the existing keyboard port as traditional keyboard input. PC/AT, PS/2 Keyboard Wedge For the keyboard wedge solution, the scanner must work with the existing keyboard concurrently.
PS/2 Keyboard Wedge Connection Plug the 5P DIN female connector of the slave cable into the 5P DIN male connector of the main cable of the scanner. Then connect the rest of the connectors to the computer keyboard port and PS/2 keyboard.
Page 13
AC power adapter to the side power jack of the D-sub connector. You will hear the power-on beep twice to signal that the scanner is ready for bar code reading. Scan the “ RS-232 Serial Interface ” bar code to configure the scanner to perform the RS-232 serial interface operation.
Make sure your computer has a USB port and the operating system is Windows or above. Plug the RJ45 phone plug of the scanner main cable into the USB keyboard cable converter. Plug the 4-pin USB Type A connector into the desired USB port of your computer.
3. Programming the Scanner There are two ways to configure the IT3220 or the VT3060/3080 – either using HHP SET bar codes in this user’s guide. Via HHP SET HHP SET is a unique software utility designed to operate under Microsoft Windows 95, 98, NT or above.
Page 16
While you are asking HHP SET to do the “Download,” “Upload,” and “Diagnostic” with the scanner, HHP SET will ask you to use the scanner to scan the Host Link Command for initial handshaking with HHP SET and then perform your desired action.
Editor’s functions via scanning the menu’s bar code. The full-feature Data Editor is only available through HHP SET, which gives you the freedom of modifying the scanned data anyway you like, and allows you to integrate the scanner into any existing application. Data Format Editor The ultra powerful data editing functions provided by the Data Editor are controlled by user-defined rules.
Page 18
The bar code label is a 16-digit Code 39 that contains a 6-digit date code, a 6-digit serial number, and a 4-digit unit price (in that order). The scanner can do the following for you without software modification: Check the bar code to see if it is Code 39 or not. Reject any codes that are not Code 39.
Page 19
Programming the Scanner Set ”Added Field” to “Insert 3 Added Fields.” Set “AF1” (Added Field 1) to “AA.” Set “AF2” to “S/N:.” Set “AF3” to “TAB (Hex 09).” ”Transmission Sequence” user defined transmission sequence to “LF,” “AF3,” “AF1,” “F2,” “AF3,” “AF2,” “F3,” and...
Code bar codes, which are found on the foldout section in the back of the book, each programmable family is contained on one page, and each page includes all of the bar codes needed to program the scanner. Refer to the flow chart on page 3-8 for further clarification. System Command...
Page 21
Flash Memory ASIC or non-volatile memory, then issues the completion beep (3 short beeps). Please note that the scanner will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END.” Please do not turn off the power before the completion beep.
Page 22
If indicated (If necessary) Repeat Want to select another Selection programming family? Exit programming mode. Scan “END” Programming the Scanner Scan “PROGRAM” Scan One of Family Codes (1st) Scan Several Option Codes (2nd) Scan One or Several Option Codes Repeat...
USB keyboard interface is only supported by Windows 98, Windows 2000 or above and Apple iMac system. *Supported by Japanese Version only. All other interfaces are supported by both the US/European and Japanese units. Programming the Scanner Host Interface Selection ♦...
Page 24
Programming the Scanner User Defined Code ID This section allows the user to define and program a Code ID that is different from the Code ID default. To specify a one-character Code ID, scan in the 2-digit hex value for that character. Then scan “END.” The hex value can be determined by referring to the HEX/ASCII Reference Table on page A-6.
Symbol ID : 2 character UPC-E (default=E0) EAN-8 (default=FF) To determine the hex value for the “Character,” refer to the HEX/ASCII Table found on page A-6. Programming the Scanner Symbology Programming ♦ User Defined Code ID ♦ Parameter Selection 3-11...
Page 26
To further ensure fast, accurate readings, you can complete more complex configurations via full-feature the Data Editor. To configure the full-feature the Data Editor, you must use the HHP SET, a Windows Programming the Scanner Symbology Programming ♦ Code ID Transmission and Symbology Enable ♦ Parameter Selection ® 95/98/NT based software utility specially designed for the scanner. 3-12 END(Exit) Option Code...
Page 27
* Selecting Full ASCII Code 39 disables Code 32 (both options may not be enabled at the same time). Code 39 and full ASCII may be enabled at the same time, and Code 32 and Code 39 standard my be enabled at the same time. Programming the Scanner Symbology Programming ♦...
Page 28
Scan 2 digits from the option code chart in the Appendix. Default (99) Codabar Max. Length Maximum length Scan 2 digits from the option code chart in the Appendix. FACTORY DEFAULT Programming the Scanner Symbology Programming ♦ Codabar/NW-7 Setting ♦ Parameter Selection 3-14 END(Exit)
Page 29
UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option. WPC Selection Basic Disable (UPC/EAN/JAN/CAN) Length Check Digit UPC-A UPC-E EAN/JAN/CAN-13 EAN/JAN/CAN-8 Programming the Scanner Symbology Programming ♦ UPC-A & UPC-E Setting ♦ Parameter Selection Disable With 2-digit Numeric System Addendum 3-15 END(Exit) Option Code...
Page 31
FACTORY DEFAULT The scanner can decode almost all Code 2 of 5 symbologies automatically. However, since the Code 2 of 5 encoding algorithm is not very robust, we recommend that you select only one kind of Code 2 of 5 for reading, or set limited maximum and minimum reading lengths for reading.
Page 32
Scan 2 digits from the option code chart in the Appendix. Code 93 Max. Length Default (99) Maximum length Scan 2 digits from the option code chart in the Appendix. FACTORY DEFAULT Programming the Scanner Symbology Programming ♦ Code 11 & Code 93 Setting ♦ Parameter Selection 3-18 END(Exit)
Page 33
Scan 2 digits from the option code chart in the Appendix. Code 128/EAN-128 Max. Length Default (99) Maximum length Scan 2 digits from the option code chart in the Appendix. FACTORY DEFAULT Programming the Scanner Symbology Programming ♦ MSI/Plessey, Code 128 & UCC/EAN 128 Setting ♦ Parameter Selection 3-19 END(Exit)
Page 34
Scan 2 digits from the option code chart in the Appendix. Default (99) Telepen Max. Length Maximum length Scan 2 digits from the option code chart in the Appendix. FACTORY DEFAULT Programming the Scanner Symbology Programming ♦ UK/Plessey & Telepen Setting ♦ Parameter Selection 3-20 END(Exit)
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-23 first. Keyboard Interface Message String : Preamble Data Length 1-15 characters 2-3 digits Programming the Scanner Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Parameter Selection Prefix Symbol ID Scanned Data...
Page 36
Scan 2 digits from the option code chart in the Appendix. None Intercharacter Delay 00-99 msec. Scan 2 digits from the option code chart in the Appendix. FACTORY DEFAULT Programming the Scanner Keyboard Interface Control Parameter Selection 3-22 END(Exit) Option Code...
Page 37
Please check the actual Caps Lock state in use while the software application is running. If the Caps Lock state is off, select the “Caps Lock Off” state, then the scanner will perform normal data transmission. If the Caps Lock state is on, select the “Caps Lock On” state. If you select “Auto Detect,” the scanner performs special transmission handshaking without changing the status of the Caps Lock switch.
Preamble Data Length 1 character 1-15 characters 2-3 digits Programming the Scanner Serial Interface Control ♦ Record Suffix, Handshaking & Time Out Setting ♦ Parameter Selection Prefix Symbol ID Scanned Data Suffix Symbol ID 1 or 2 characters variable length 1 or 2 characters 1-15 characters...
Page 39
This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the scanner waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, the scanner will re-send the data until receiving ACK.
Any other characters that are not available in Code 39 symbology set will be skipped. [ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set will be translated as Space. Programming the Scanner Wand Emulation Control ♦...
When this operation mode is selected, the scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation. While the scanner is in the idle state, there is only maximum 500uA standby current for the entire reading device.
Page 42
This parameter provides the user with a helpful tool to use when the printing quality of the bar code is poor. This is a programmable feature in IT3220 units with software revision AXX, and 3060/80B with software revision CXX. Units using later software revisions [IT3220 (revision BXX) and VT3060/80B (DXX) automatically without any extra programming.
Poor (critical) printing quality Please read the Scanning Tolerance information on page 3-28 before attempting to program this feature. (Printing Quality Control) FACTORY DEFAULT Programming the Scanner Operation Control ♦ Trigger Mode, Buzzer Tone, Scanning Tolerance ♦ Parameter Selection 3-29...
Page 44
Reread Delay This feature is designed to inhibit the scanner from reading the same bar code within a certain period of time. The time period can be programmed for immediate, short, medium, or long time out duration. Another selection, Force Verification, does not allow reading of the same bar code twice even after a very long duration.
Page 45
The Debounce Time Control feature is available in the IT3220 (prior to software revision B) and in the VT3060/3080 (prior to software revision D). Units using later software revisions perform this function automatically. Programming the Scanner Operation Control ♦ Reread Delay, Scan Voting ♦...
A Condensed Version Data Editor is provided here in the manual and is utilized by scanning the programming bar codes. When Data Pass Control is disabled, all input data must conform to an edited format or the scanner does not transmit the input data to the host.
Page 47
Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of the data formatter. To determine the hex value for the “Character,” refer to the HEX/ASCII Table on page A-6 Refer to page 3-12 for for the 2-digit symbology option code. Programming the Scanner Condensed Data Editor ♦ Data Formatter ♦...
Page 48
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the scanner will not transmit the data to the host computers, but will instead issue 3 long beeps for verification error and skip the scanned data.
Page 49
Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of Data Replacer. To determine the hex value for the “Character,” refer to the HEX/ASCII Table listed on page A-6. Refer to page 3-12 for 2-digit symbology option code. Programming the Scanner Condensed Data Editor ♦ Data Replacer Settings ♦...
Page 50
Please refer to the next page for information about the “Bar Code Selection” and “Position Calculation” of Data Organizer. To determine the hex value for the “Character,” refer to the HEX/ASCII Table listed on page A-6. Refer to page 3-12 for 2-digit symbology option code. Programming the Scanner Condensed Data Editor ♦ Data Organizer Settings ♦...
Page 51
You can use the Condensed Data Editor for an advanced transmission arrangement with one or all bar code symbologies. If you scan “00” to select all types, the scanner arranges all incoming data to meet your pre-defined format. If you want to select only one type of bar code, please select one of the option codes listed below.
Page 52
Scan “1st Replacement” and set the identified position to “00,” then replaced character to “41” (Hex value for A). At this point the data string is as follows: Programming the Scanner A81025[TAB]SN123456[TAB]9876[TAB]. We still need to delete the 98 from the string to get the desired output.
Fax: (704) 566-9904 Customer Service For service in Europe, please contact your HHP representative or your local distributor. European Office Hand Held Products, Inc. Nijverheidsweg 9 5627 BT Eindhoven The Netherlands Telephone: +31 (0) 40 29 01 600 Fax: +31 40 242 5672 United Kingdom Office Hand Held Products, Inc.
For service in Asia, please contact your HHP representative or your local distributor. Asia Pacific Office Hand Held Products, Inc. 10/F Tung Sun Commercial Centre 194-200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852-2511-3050 or 2511-3132 Fax: Int+852-251-1355 For service in Japan, please contact your HHP representative or your local distributor.
Page 55
North America: Telephone: (315) 685-2476 (8 a.m. to 8 p.m. EST) or in the U.S.: (800) 782-4263 Fax number: (315) 685-4960 E-mail: tech_support@hhp.com Europe: Telephone- European Ofc: Int+31 40 242 4486 U.K. Ofc: Int+44 1925 240055 E-mail: euro_support@hhp.com Asia: Telephone: Int+852-2511-3050 or 2511-3132 E-mail: asia_support@hhp.com Customer Service Latin America:...
5. Limited Warranty Hand Held Products, Inc., d/b/a HHP (“HHP”) warrants its products to be free from defects in materials and workmanship and to conform to HHP’s published specifications applicable to the products purchased at the time of shipment. warranty does not cover any HHP product which is (i) improperly installed or used;...
Page 57
Limited Warranty AMOUNT PAID TO HHP FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HHP MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,...
Appendix A This chapter gives the most up-to-date description of scanner accessories, including various Host Interface Cable Adapters, Beeping Indications, and the Keyboard Function Code Table. Also, all necessary bar code commands are printed in the foldout of the back cover of this manual.
Page 59
Illustration Description PC/AT KB Wedge Cable Converter - Desktop PC/AT KB Wedge - 5P DIN Male & Female Connectors PS/2 KB Wedge Cable Converter - PS/2 KB Wedge - DOS/V KB Wedge - 6P Mini-DIN M&F Connectors USB KB Cable Converter - USB KB Direct Link - 4P USB Type A Male Connector Apple ADB Keyboard Wedge...
Page 60
Appendix A Illustration Description RS-232 Serial Wedge Cable Converter - 25P D-Sub M&F Connectors - Embedded Power Jack Notebook PS/2 Keyboard Direct Link Cable Converter - 6P Mini-DIN Male Connector Wand Emulation Interface Cable Converter - 9P D-Sub Female Connector...
Beeping Indications Descriptions Internal or operation memory error Internal fatal error Beginning the normal operation Entering the programming mode (Program) Exiting the programming mode (End) Completing to store the parameters Starting the master default and group default Completing the master default and group default Completing the system information listing Good reading Programming error (Invalid programming scan)
ENTER (Carriage Return) To emulate the key functions above, program the scanner by using the corresponding ASCII hex value. For example, if you want to program in a suffix of a TAB, you would follow the directions for programming a suffix on page 3-22. For option code, scan “...
ASCII Input Shortcut To configure the user definable parameters of the scanner via the programming bar codes, you will be asked to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details.
Bar Code Command Menu Option Code : “0 – 9”, “A – F” Appendix A System Command FIN (Finish) END (Exit) (System List) SYSLIST (Master Default) M_DEFAULT...
Appendix A Bar Code System Command Bar Code System Command Set PC/AT, PS/2 Keyboard Wedge System Information List (SYSLIST) USB Keyboard Interface Keyboard Replacement Factory Default Setting (M_DEFAULT) RS-232 Serial Interface HHP SET Host Link...