Specifications; Introduction; Unpacking - Garland SRW286A Installation & Operating Instructions Manual

Starfire sentry combination range
Table of Contents

Advertisement

Oven Interior Dimensions
Height
Width
13-12"
26-1/4"
(343mm)
(667mm)
Hot Top
BTU
kW
25,000
7.32
50,000
NOTE: Installation clearance reductions are applicable only where local codes permit.
This product is not approved for residential use.
Commercial cooking equipment requires an adequate ventilation system. For additional infor-
mation, refer to the National Fire Protection Association's standard NFPA96.
This equipment must be installed and adjusted by a
competent person in accordance with the law. Failure
to install appliances correctly could lead to prosecution.
It is in your own interests and that of safety to ensure
that the law is complied with. Your Garland Dealer is
well qualified to provide this service.
This appliance should be given regular care and
maintenance. Periodic inspections by the dealer or a
qualified service company are recommended to check
temperature, burner adjustments and to ensure moving
parts are operative. Wherever possible avoid overheating
idle equipment as this is the primary cause of increased
service cost.
"Regular maintenance ensures peak performance."

Unpacking:

1. Check crate for possible damage sustained during
transit. Carefully remove unit from crate and again
check for damage. Any damage to the appliance
must be reported to the carrier immediately.
4517957 Rev. 2 (06/05)

SPECIFICATIONS

Entry Clearance
Depth
Crated
22"
43"
(559mm)
(1105mm)
Input Ratings
Griddle
Oven
BTU
kW
BTU
14.65
30,000

INTRODUCTION

Installation Clearances
Uncrated
Sides
37-7/8"
7"
(648mm)
(178mm)
Total
kW
BTU
KW
8.79
105,000
30.76
2. The wires for retaining the burners and other
packing material must be removed from units. Any
protective material covering stainless steel parts
must also be removed.
3. All ranges are shipped from the factory with casters
fitted.
4. The type of gas and the supply pressure that the
equipment was set up for at the factory is noted on
the data plate and on the packaging. This type of
gas supply must be used.
5. Do not remove permanently affixed labels, warnings
or data plates from the appliance, for this may
invalidate the manufacturer's warranty.
NOTE: Many parts of the equipment are raw steel i.e
griddle top and solid hot top and can react with moisture
forming rust. This is normal and not considered a defect.
Clean with a stainless steel fiber pad. A light coating of
salt free oil may be applied to prevent further rusting.
Shipping
Manifold
Weight
Inlet Size
Rear
6"
584lbs.
3/4" NPT
(152mm)
(265kg)
Operating Pressure
Natural
"WC
mbar
"WC
4.5
11
10
Female
Propane
mbar
25
Page 5