Garland S680 SERIES Installation And Service Manual

Garland S680 SERIES Installation And Service Manual

Restaurant ranges and salamanders

Advertisement

INSTALLATION AND
SERVICE MANUAL
GARLAND S680, SS680 &
SU680 SERIES RESTAURANT
RANGES AND SALAMANDERS

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com .
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice .
GARLAND COMMERCIAL INDUSTRIES, LLC
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # P152 Rev 1 (01/13/10)
Part # P152 Rev 1 (01/13/10)
APPLIANCE
WARNING:
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE .
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED .
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES .
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION .
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE .
GARLAND COMMERCIAL RANGES, LTD .
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
© 2004 Garland Commercial Industries, LLC
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S680 SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garland S680 SERIES

  • Page 1: For Your Safety

    Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DIMENSIONS AND SPECIFICATIONS .
  • Page 4: Dimensions And Specifications

    DIMENSIONS AND SPECIFICATIONS, MODELS S,SU & SS684 Nominal Amps Total Kw Model Load 208V/1Ph 208V/3 Ph 240V/1Ph 240V/3 Ph 400 V/3N 415V/3N S684* — — SS/SU684** SS/SU684RC2*** Salamander N/A***** Broiler**** *(All purpose tubular elements) **(Sealed -top elements, Model # SS684 in North America) *** Maximum on any 684 series range . ****Add when wired to range base (SER/SUER-680) *****Note: For 208V/1phase the salamander cannot be wired into the range .
  • Page 5 DIMENSIONS AND SPECIFICATIONS, MODELS S,SU & SS686 Nominal Amps Total Kw Model Load 208V/1Ph 208V/3 Ph 240V/1Ph 240V/3 Ph 400 V/3N 415V/3N S686* — — S686RC — — SS/SU686** SS/SU686RC Salamander Broiler*** *Tubular elements; **Sealed -top elements, Model # SS686 in North America; ***Add when wired to range base (SER/SUER-680) Installation Exterior Dimensions Oven Interior Dimensions...
  • Page 6 DIMENSIONS AND SPECIFICATIONS, RANGE MODELS Range Suffix Definitions S/SS/SU 686/684 RC (2) -(1,2,3) (L,C,R) -(12,24,36) (L,C,R) -12 = 12" (305 mm) wide griddle -24 = 24" (610 mm) wide griddle -36 = 36" (915 mm) wide griddle - L = griddle on left hand side of range - C = griddle in center of range - R = griddle on right hand side of range -1 = 12"...
  • Page 7 DIMENSIONS AND SPECIFICATIONS, MODELS SERC, SER-680 TOTAL AMPS Model Total Kw Load 208V/1Ph 208V/3 Ph 240V/1Ph 240V/3 Ph 400 V/3N 415V/3N SERC, SER-680 wired independently Installation Notes: Clearances from combustible surfaces should be minimum 7” (178mm) from sides, 2” (51mm) from back . *Note: 3 phase ratings apply to SERC and SER-680 ordered separately .
  • Page 8: Introduction

    . Carefully remove the unit from the crate and manual or on our web site: http://www .garland-group .com . again check for damage . Any damage to the appliance must be reported to the carrier immediately .
  • Page 9: Installation

    2” (51mm) connection . If the restraint is disconnected, be sure to reconnect it after the range has been returned to its * NOTE: Garland recommends equipment be installed under originally installed position . a ventilation canopy . Ventilation Air...
  • Page 10: Assembly Of Backguard/High Shelf

    Code Requirements are set to the ON (1) position . The Garland S/SS680 series complies with the standards CSA 1 . Ensure that all controls are in the OFF position and turn C22 .2 no .109 – latest edition, the UL197 – latest edition and on the main electrical supply .
  • Page 11: Thermostat Calibration

    MAINTENANCE AND CLEANING Regular servicing by a competent person is recommended to ensure safe and efficient performance of the appliance . WARNING: Turn off the electrical mains before Calibration Increase commencing any service work . Screw Head Thermostat Calibration Oven Decrease It is normal for an electromechanical thermostat to cycle with a 45°F - 50°...
  • Page 12: Replacement Of Parts

    MAINTENANCE AND CLEANING continued Miscellaneous 3 . Wipe exposed cleanable surfaces with a mild detergent and hot water . Stubborn residue may be removed with 1 . Grease the door hinges and check for loose fasteners . a light weight non-metallic scouring pad . Stainless steel Tighten as necessary .
  • Page 13: Motor

    REPLACEMENT OF PARTS continued Motor blower wheel to the motor shaft and remove the wheel . 5 . Remove the four (4) screws securing the motor mount 1 . Open the door . plate to the oven casing back and pull the plate froward 2 .
  • Page 14: Oven Diagnostics

    TROUBLE SHOOTING continued Oven Diagnostics PROBLEM POSSIBLE CAUSE SOLUTION Oven too hot or not hot enough . Thermostat out of calibration . Check Thermostat/replace thermostat . RC Oven Diagnostics PROBLEM POSSIBLE CAUSE SOLUTION Cook/Cool Down Switch set to No Power to Oven . Check power supply .
  • Page 15: Appendix

    APPENDIX Wiring Diagrams and Loading Charts Part # P152 Rev 1 (01/13/10) Page 15...
  • Page 16 TB1-10a TB1-12b TB1-11a TB1-10c TB1-10a Page 16 Part # P152 Rev 1 (01/13/10)
  • Page 17 Part # P152 Rev 1 (01/13/10) Page 17...
  • Page 18 Page 18 Part # P152 Rev 1 (01/13/10)
  • Page 19 TB1-10a TB1-12b TB1-11a TB1-10c TB1-10a Part # P152 Rev 1 (01/13/10) Page 19...
  • Page 20 Page 20 Part # P152 Rev 1 (01/13/10)
  • Page 21 Part # P152 Rev 1 (01/13/10) Page 21...
  • Page 22 TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 22 Part # P152 Rev 1 (01/13/10)
  • Page 23 Part # P152 Rev 1 (01/13/10) Page 23...
  • Page 24 Page 24 Part # P152 Rev 1 (01/13/10)
  • Page 25 Part # P152 Rev 1 (01/13/10) Page 25...
  • Page 26 TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 26 Part # P152 Rev 1 (01/13/10)
  • Page 27 Part # P152 Rev 1 (01/13/10) Page 27...
  • Page 28 Page 28 Part # P152 Rev 1 (01/13/10)
  • Page 29 Part # P152 Rev 1 (01/13/10) Page 29...
  • Page 30 TB2-10a TB2-12b TB2-11a TB2-10d TB2-10a TB1-10a TB1-12b TB1-11a TB1-10c TB1-10a Page 30 Part # P152 Rev 1 (01/13/10)
  • Page 31 Part # P152 Rev 1 (01/13/10) Page 31...
  • Page 32 Page 32 Part # P152 Rev 1 (01/13/10)
  • Page 33 Part # P152 Rev 1 (01/13/10) Page 33...
  • Page 34 MODEL Phase grouping Loading chart SS684STD NO SALAMANDER domestic (delta) load Total kW voltage KW X-Z kW X-Y kW Y-Z A 1 phase Top 1, Top 2 Top 3 32 .70 13 .80 9 .45 9 .45 97 .37 97 .37 78 .69 157 .21 Top 4, Oven 1...
  • Page 35 MODEL Phase grouping Loading chart SS684-2R-12L NO SALAMANDER domestic (delta) load Total kW voltage kW X-Z kW X-Y Kw Y-Z A 1 phase Top 1, Top 4, Top 5 28 .95 10 .05 9 .45 9 .45 81 .20 81 .20 78 .69 139 .18 SS684-1L-24R...
  • Page 36 TB2-10a TB2-12b TB2-11a TB2-10d TB2-10a TB1-10a TB1-12b TB1-11a TB1-10c TB1-10a Page 36 Part # P152 Rev 1 (01/13/10)
  • Page 37 Part # P152 Rev 1 (01/13/10) Page 37...
  • Page 38 Page 38 Part # P152 Rev 1 (01/13/10)
  • Page 39 Part # P152 Rev 1 (01/13/10) Page 39...
  • Page 40 MODEL NO SALAMANDER Phase Grouping Loading Chart SU684 STD NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A 1 phase Top 1 , Top 2, Top 3 400V 3N~ 32 .7 13 .8 9 .45...
  • Page 41 MODEL NO SALAMANDER Phase Grouping Loading Chart SU684-2L-12R NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A 1 phase SU684-1R-12L Top 1, Top 2, Top 5 400V 3N~ 28 .95 10 .05 9 .46...
  • Page 42 TB2-10a TB2-12b TB2-11a TB2-10d TB2-10a TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 42 Part # P152 Rev 1 (01/13/10)
  • Page 43 Part # P152 Rev 1 (01/13/10) Page 43...
  • Page 44 Page 44 Part # P152 Rev 1 (01/13/10)
  • Page 45 Part # P152 Rev 1 (01/13/10) Page 45...
  • Page 46 MODEL Phase grouping Loading chart SS684RC STD NO SALAMANDER domestic (delta) load Total kW voltage kW X-Z kW X-Y kW Y-Z A 1 phase Top 1, Top 2, Top 3 33 .35 13 .80 10 .10 9 .45 99 .91 97 .37 81 .41 160 .34...
  • Page 47 MODEL Phase grouping Loading chart SS684RC-2L-12R NO SALAMANDER domestic (delta) load Total kW voltage kW X-Z kW X-Y kW Y-Z Al1 phase SS684RC-1R-24L Top 1, Top 2, Top 5 28 .35 10 .05 8 .85 9 .45 78 .74 81 .20 76 .21 136 .30 Top 3, Oven 1...
  • Page 48 TB2-10a TB2-12b TB2-11a TB2-10d TB2-10a TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 48 Part # P152 Rev 1 (01/13/10)
  • Page 49 Part # P152 Rev 1 (01/13/10) Page 49...
  • Page 50 Page 50 Part # P152 Rev 1 (01/13/10)
  • Page 51 Part # P152 Rev 1 (01/13/10) Page 51...
  • Page 52 MODEL Phase grouping Loading Chart SU684RC STD NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A 1 phase Top 1, Top 2, Top 3 400V3N~ 33 .35 13 .8 10 .1 9 .45 60 .00...
  • Page 53 MODEL Phase grouping Loading Chart SU684RC-2L-12R NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A 1 phase SU684-1R-24L Top 1, Top 2, Top 5 400V3N~ 29 .6 10 .05 10 .10 9 .45 43 .70...
  • Page 54 TB2-9c TB2-10a TB2-12b TB2-11b TB2-11a TB1-10d TB2-10c TB2-10a TB2-10b TB2-9a TB2-9b TB2-8c TB2-8a TB2-8b TB2-7b TB2-7a TB2-10b TB2-10e TB2-10c TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 54 Part # P152 Rev 1 (01/13/10)
  • Page 55 Part # P152 Rev 1 (01/13/10) Page 55...
  • Page 56 Page 56 Part # P152 Rev 1 (01/13/10)
  • Page 57 Part # P152 Rev 1 (01/13/10) Page 57...
  • Page 58 MODEL Phase grouping Loading chart SS684RC2 STD NO SALAMANDER domestic (delta) load Total kW voltage kW X-Z kW X-Y kW Y-Z A 1 phase Top 1, Top 2, Top 3 34 .00 13 .80 10 .10 10 .10 99 .91 99 .91 84 .10 163 .46...
  • Page 59 MODEL Phase grouping Loading chart SS684RC2-2L-12R NO SALAMANDER domestic (delta) load Total kW voltage kW X-Z kW X-Y kW Y-Z Al1 phase SS684RC2-1R-24L Top 1, Top 2, Top 5 30 .25 10 .05 10 .1 10 .1 83 .90 83 .90 84 .10 145 .43 Top 3, Oven 1...
  • Page 60 TB2-9c TB2-10a TB2-12b TB2-11b TB2-11a TB1-10d TB2-10c TB2-10a TB2-10b TB2-9a TB2-9b TB2-8c TB2-8a TB2-8b TB2-7b TB2-7a TB2-10b TB2-10e TB2-10c TB1-9c TB1-10a TB1-12b TB1-11b TB1-11a TB1-10d TB1-10c TB1-10a TB1-10b TB1-9a TB1-9b TB1-8c TB1-8a TB1-8b TB1-7b TB1-7a TB1-10b TB1-10e TB1-10c Page 60 Part # P152 Rev 1 (01/13/10)
  • Page 61 Part # P152 Rev 1 (01/13/10) Page 61...
  • Page 62 Page 62 Part # P152 Rev 1 (01/13/10)
  • Page 63 Part # P152 Rev 1 (01/13/10) Page 63...
  • Page 64 MODEL Phase grouping Loading chart SU684RC2 STD NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A 1 phase Top 1, Top 2, Top 3 400V 3N~ 13 .8 10 .1 10 .1 60 .00...
  • Page 65 MODEL Phase grouping Loading chart SU684RC2-2L-12R NO SALAMANDER export (wye) load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A lphase SU684-1R-24L Top 1, Top 2, Top 5 400V 3N~ 30 .25 10 .05 10 .1 10 .1 43 .70...
  • Page 66 SWITCH HEAT 1.165 1.165 1.165 1.165 1.165 1.165 SWITCH HEAT Page 66 Part # P152 Rev 1 (01/13/10)
  • Page 67 Part # P152 Rev 1 (01/13/10) Page 67...
  • Page 68 SWITCH HEAT 1.165 1.165 1.165 1.165 1.165 1.165 SWITCH HEAT Page 68 Part # P152 Rev 1 (01/13/10)
  • Page 69 Part # P152 Rev 1 (01/13/10) Page 69...
  • Page 70 Page 70 Part # P152 Rev 1 (01/13/10)
  • Page 71 Part # P152 Rev 1 (01/13/10) Page 71...

Table of Contents