Step 9. Commission the
System
After installing the control unit you should
commission the alarm system as follows:
1. Use the Installer Menu (see Chapter 4)
to teach the control unit the identity of
its radio detectors and any other
peripherals. See the installation
instructions supplied with each detector
or peripheral.
2. Install detectors and peripherals at their
selected locations.
3. Use the Installer Menu – Test (see
Chapter 5) option to:
a) carry out a walk test of the detectors.
b) test the operation of any other
peripherals.
4. Program the system to suit user
requirements. See the i-on40
Programming Reference for a detailed
description of the Installer Menu.
5. Assemble and close the control unit:
a) Hook the lid of the control unit into
the bottom of the case.
b) Close the lid and then tighten the two
fixing screws.
1
Figure 23 Replacing the control unit lid.
6. Leave the Installer Menu.
The red LEDs should go out, and the rim
of the navigation keys glow green. The
system is now ready to hand over to the
user.
7. Instruct the user on how to operate the
system. See the i-on40 User Guide and
the i-on40 Administrator's Guide. If
necessary, show them how to set the
time and date on the system.
Note that you can obtain the
Administrator's Guide from
www.coopersecurity.co.uk.