Connecting A Redundant Drive Loop To The Fastt700 Storage Server; Connecting A Second Redundant Drive Enclosure Group (Loops C And D) - IBM TotalStorage FAStT700 Installation Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT700:
Table of Contents

Advertisement

Figure 31. Connecting a second redundant drive enclosure group (loops C and D)
5. Continue with "Connecting a redundant drive loop to the FAStT700 Storage

Connecting a redundant drive loop to the FAStT700 Storage Server

Use the following procedure to connect a redundant drive loop to the FAStT700
Storage Server. You will need two fiber-optic cables for each redundant pair of
loops (for example, loop A and loop B) that you are connecting to the FAStT700
Storage Server.
1. Connect drive loop A to the FAStT700 Storage Server, as shown in Figure 32 on
®
30
IBM
TotalStorage
FAStT700 Fibre Channel Storage Server: Installation Guide
2).
Loop A
Drive
enclosure
group 1
Storage server
Out
In
Server".
page 31.
Starting with the last drive enclosure in loop A, connect the In port on the left
ESM board to the Out (upper) port on drive mini hub 4 on the FAStT700
Storage Server.
Loop B
Drive
enclosure
group 1
Out
In
Drive
enclosure
group 2
Loop A
Loop B
Storage server
Loop C
Loop D

Advertisement

Table of Contents