Recording Profiles - Bosch Starlight 7000 HD Operation Manual

Mic ip starlight 7000 hd / mic ip dynamic 7000 hd series
Hide thumbs Also See for Starlight 7000 HD:
Table of Contents

Advertisement

MIC IP starlight 7000 HD, MIC IP
dynamic 7000 HD
2.
15.26

Recording Profiles

You can define up to ten different recording profiles. You will then use these recording profiles
in the recording scheduler, where they are linked with the individual days and times (see
Recording Scheduler, page 68).
Notice!
You can change or add to the recording profile description on the tabs on the Recording
Scheduler page (see Recording Scheduler, page 68).
1.
2.
3.
4.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the Pre-
alarm option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
If you select Off, no automatic recording takes place.
Caution!
You can specify limitations for overwriting older recordings in Continuous mode by
!
configuring the retention time (see Maximum Retention Time, page 68).
Standard profile
From this field, you can select the encoder profile to be used for recording (see Encoder
Profile).
Notice!
The recording profile can deviate from the standard setting Active profile and is only used
during an active recording.
Pre-alarm time
You can select the required pre-alarm time from the list field.
Post-alarm time
You can select the required post-alarm time from the list field.
Post-alarm profile
You can select the encoder profile to be used for recording during the post-alarm time (see
Encoder Profile).
The Standard profile option adopts the selection at the top of the page.
Alarm input / Analysis alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
Bosch Security Systems
Click the Remove button below the list. The storage medium is deactivated and removed
from the list.
Click one of the tabs to edit the corresponding profile.
If necessary, click the Default button to return all settings to their default values.
Click the Copy Settings button if you want to copy the currently visible settings to other
profiles. A new window will open and you can select the profiles in which you want to
copy the settings.
For each profile, click the Set button to save the settings in the unit.
Operation Manual
Configuration via IP, Advanced Mode | en
2014.09 | 1.3 | F.01U.291.520
67

Hide quick links:

Advertisement

Table of Contents
loading