Camshaft Journals And Bore; Camshaft, Cam Height (Mm); Camshaft, Pin And Housing Dimensions, And Relevant Clearances (Mm); Dynamic Balancer (On Request) - Kohler RD 441 Service Manual

Horizontal crankshaft
Table of Contents

Advertisement

96
97
98
99
Workshop Manual KD 441_cod. 1.5302.865_2

Camshaft journals and bore

Use an inside dial gauge to measure the camshaft pin housing dia-
meters.
Camshaft, pin and housing dimensions, and relevant clearances
(mm)

Camshaft, cam height (mm)

Note: Replace camshaft if cam wear exceeds the minimum given va-
lue of H, H

Dynamic balancer (on request)

The dynamic balancer is supported by two identical ball bearings
housed in the crankcase and in the gear cover on the timing side re-
spectively.
1 is the reference point for timing with the cranksaft gear (see below).
Dimensions (mm):
A
14.969÷14.980
B
14.990÷15.000
C
34.989÷35.000
D
34.958÷34.983
nd
ed_ rev. 01.
Overhauls and checking
A
17.966÷17.984
B
15.957÷15.984
C
16.000÷16.018
D
18.00÷18.018
(D-A)
0.016÷0.052
(D-A)
Limit
0.100
(C-B)
0.016÷0.061
(C-B)
0.120
Limit
H
39.75÷39.80
H
36.15÷36.20
1
H
35.85÷35.90
2
and H
by 0.1 mm.
1
2
(bearing housing diameter on crankcase
and gear cover on timing side).
5
- 45 -

Advertisement

Table of Contents
loading

Table of Contents