SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
C2 - C3 - C3 PLURIEL
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals (compressor oil) .
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5) into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4) is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal
of the cartridge (6) from its packaging and its being fitted.
Refit:
- The plastic cap (3), using tool [5] - Tighten to 1,2 ± 0,1 m.daN.
- The condenser (reclip, pushing at «b» and «c») .
- The plastic cover and the pins at «a».
- The grille (2).
- The screws (1).
Proceed to:
- Recharge the circuit (see corresponding operation) .
- Check the operation of the air conditioning (see corresponding operation) .