Table 130 SNMP System Traps (continued)
OPTION
OBJECT LABEL
fanairflow
FanAirFlowEventOn
FanAirFlowEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClear
intrusionlock IntrusionLockEventOn
loopguard
LoopguardEventOn
errdisable
errdisableDetect
errdisableRecovery
Table 131 SNMP InterfaceTraps
OPTION
OBJECT LABEL
linkup
linkUp
LinkDownEventClear
linkdown
linkDown
LinkDownEventOn
XS3900-48F User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.8.74.31.2.2
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.8.74.31.2.2
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.8.74.31.2.1
1.3.6.1.4.1.890.1.5.8.74.130.4.1
1.3.6.1.4.1.890.1.5.8.74.130.4.2
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.4.1.890.1.5.8.74.31.2.2
1.3.6.1.6.3.1.1.5.3
1.3.6.1.4.1.890.1.5.8.74.31.2.1
Chapter 36 Access Control
DESCRIPTION
Fan module and power module fan air-
flow must be in the same direction
(front-to-back or back-to-front) on the
same Switch. This trap is sent when
the airflows are not in the same
direction.
Fan module and power module fan air-
flow must be in the same direction
(front-to-back or back-to-front) on the
same Switch. This trap is sent when
the airflows return to the same
direction.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch
resets by an administrator through a
management interface.
This trap is sent when the Switch
reboots by an administrator through a
management interface.
This trap is sent when the Switch fails
to get the time and date from a time
server.
This trap is sent when the Switch gets
the time and date from a time server.
This trap is sent when intrusion lock
occurs on a port.
This trap is sent when loopguard shuts
down a port.
This trap is sent when an error is
detected on a port, such as a loop
occurs or the rate limit for specific
control packets is exceeded.
This trap is sent when the Switch
ceases the action taken on a port, such
as shutting down the port or discarding
packets on the port, after the specified
recovery interval.
DESCRIPTION
This trap is sent when the Ethernet
link is up.
This trap is sent when the Ethernet
link is up.
This trap is sent when the Ethernet
link is down.
This trap is sent when the Ethernet
link is down.
279