88
Figure 29: Flat Field Correction
Name
Visibility
Pixel Set Selector
Beginner
Load Pixel
Beginner
Coefficient
03-032-20059-01
volatile memory of the
device.
Description
This feature selects which
pixel set to load and save.
The default is reserved for
factory user to save factory
calibrated data, and can only
be read. If they want to save
another set of coefficients,
they need to set Pixel Set
Selector to a value other than
the default.
Loads the Flat Field
Correction Coefficients
(specified by the Pixel Set
Selector) from the cameras
ASCII
Command
Command
Range
sfs
Default,
set1, set2,
set3, set4,
set5, set6,
set7, set8
lpc
NA
Spyder3 Color Manual
Additional
Information
Saving and
Restoring PRNU
and FPN
Coefficients, page
53.
Saving and
Restoring PRNU
and FPN
Coefficients, page
DALSA