34
Mode 6: External Line Rate and Internally Programmable Exposure Time
Figure 13: EXSYNC controls Line Period with Internally controlled Exposure Time
CR
EXSYNC
CR = Charge Reset
Mode 7: Internally Programmable Line Rate, Maximum Exposure Time
In this mode, the line rate is set internally with a maximum exposure time.
Figure 14: Mode 7 Camera Timing
Internal SYNC set
using the ssf command
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this mode, the exposure time is set internally with a maximum line rate.
Figure 15: Mode 8 Timing
CR=Charge Reset
03-032-20059-01
Line Period
Exposure Time
Readout
Programmable period
using set command
Readout
CR Exposure Time
Frame Period
Waiting
CR
Programmable period
using set command
Line Period
Exposure Time
Readout
EXSYNC falling edge
ignored during
readout
Programmable Period
Readout
Spyder3 Color Manual
Line Period
Exposure Time
Readout
Line Period
Exposure Time
Readout
EXSYNC falling edge
ignored during
readout
Programmable Period
CR Exposure Time
Frame Period
Waiting
DALSA