Spyder3 Color Manual
Setting the Line Rate
i
Purpose:
Applies to Modes 2 and
Syntax:
7
Syntax Elements:
Notes:
Related Commands:
Example:
DALSA
Sets the camera's line rate in Hz. Camera must be operating in
exposure mode 2 or 7.
ssf f
i
Desired line rate in Hz. Allowable values are:
2k 2 tap: 300 - 18000 Hz
4k 2 tap: 300- 9000 Hz
To read the current line frequency, use the command gcp or
get ssf.
If you enter an invalid line rate frequency, an error message is
returned.