Dalsa Spyder3 User Manual page 63

Spyder3 color camera link; bilinear color line scan camera
Hide thumbs Also See for Spyder3:
Table of Contents

Advertisement

Spyder3 Color Manual
Camera Serial
No.:
Firmware
Version:
CCI Version:
FPGA Version:
Set Number:
UART Baud Rate:
Camera Link
Mode:
Mirroring Mode:
Readout Mode:
Exposure Mode:
SYNC Frequency:
Exposure Time:
CCD Direction:
Video Mode:
Region Of
Interest X:
Region Of
Interest Width:
End-Of-Line
Sequence:
FFC Coefficient
Set:
FPN
Coefficients:
PRNU
Coefficients:
Input LUT:
Input LUT
Coefficients
Set:
Number Of Line
Samples:
Upper Threshold:
Lower Threshold:
Current Tap:
Colour:
Current Light:
DALSA
xxxxxxxx
xx-xxx-xxxxx-xx
xx-xxx-xxxxx-xx
xx-xxx-xxxxx-xx
1
9600
clm:2
(2 taps,
8 bits)
0, left to right
Off
7
1600.00 Hz
200.00 uSec
internal/forward
video
1
2048 or 4096
off
1
on
on
off
0
1024
3600
400
0
RGB
unadjusted
Camera serial number
Firmware design revision number
CCI version number
FPGA revision number
Last user set loaded, set with sus command
Serial communication connection speed set with the
sbr command
Current bit depth setting set with the clm command
Tap readout direction: left to right, or right to left. Set
with the smm command
Current readout mode status. Set using the srm
command
Current exposure mode value set with the sem
command
Current line rate. Value is set with the ssf command
Current exposure time setting. Value is set with the
set command
Current direction setting set with scd command
Current video mode value set with the svm command
The starting horizontal position of Region Of Interest.
Set with srx command
Width of Region Of Interest in pixel. Set with srw
command
States whether an end of line sequence is turned on or
off. Set using the els command
Current pixel coefficient set loaded, set with sfs
command
States whether FPN coefficients are on or off. Set with
the epc command
States whether PRNU coefficients are on or off. Set
with the epc command.
States whether LUT correction is on or off. Set with eil
command
Current LUT coefficient set loaded
Number of lines samples set with the css command
Upper threshold value set with the sut command
Lower threshold value set with the slt command
Current tap, set with sct command
Current color, set with scl command
Current light source, set with sls command
63
03-032-20059-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spyder3 sc-30-02k80-00-rSpyder3 sc-30-04k80-00-r

Table of Contents