Dalsa Spyder3 User Manual page 68

Spyder3 color camera link; bilinear color line scan camera
Hide thumbs Also See for Spyder3:
Table of Contents

Advertisement

68
Mnemonic
set exposure mode
set exposure time
set FFC set number
set line mode
set light source
set lower threshold
set mirroring
mode
set pixel window
width
set pixel X position
set readout mode
set ROI width
set ROI X
set subtract
background
set sync frequency
03-032-20059-01
Syntax
Parameters
sem
m
set
f
sfs
i
slm
m
sls
i
slt
i
smm
i
spw
i
spx
i
srm
i
srw
i
srx
i
ssb
i
ssf
i
Description
Sets the exposure mode:
2 = Internal SYNC, internal PRIN,
programmable line rate and exposure
time using commands ssf and set
3 = External SYNC, internal PRIN,
maximum exposure time
4 = Smart EXSYNC
6 = External SYNC, internal PRIN,
programmable exposure time
7 = Internal programmable SYNC,
maximum exposure time. Factory setting.
8 = Internal SYNC, internal PRIN,
programmable exposure time. Maximum
line rate for exposure time.
Sets the exposure time. Refer to the
camera help screen (h command) for
allowable range.
Set to load/save using the lpc, wpc, wfc
commands.
Set the line trigger mode as either
external or internal:
e—external line trigger
i—internal line trigger.
Set current light source in a range of 0 to
5.
The pixels below the lower threshold are
checked for and reported in the end-of-
line sequence in a range from 0-4095.
Set tap readout direction: left to right, or right
to left
Set horizontal width used in gl, gla, dpc
commands.
Set horizontal starting position used in gl,
gla, dpc commands.
Set the readout mode in order to clear out
dark current charge in the vertical transfer
gates before the sensor is read out.
0 = Auto.
1 = Dark current clear.
2 = Immediate readout. Does not clear
dark current.
Specify the width of the ROI.
Specify the starting X position of the ROI.
Subtract the input value from the output
signal.
i = Subtracted value in a range from 0 to
4095.
Set the frame rate to a value from 300 Hz
to 18000 Hz (2k model). Value rounded
up/down as required.
Spyder3 Color Manual
DALSA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spyder3 sc-30-02k80-00-rSpyder3 sc-30-04k80-00-r

Table of Contents