66
Mnemonic
end of line
sequence
enable PRNU
coefficients
get command log
get camera model
get camera
parameters
get camera serial
get camera version
get value
get help
get line
get line average
get signal
frequency
get status led
Help
load pixel
coefficients
Load user settings
reset camera
03-032-20059-01
Syntax
Parameters
els
i
epc
i
gcl
gcm
gcp
gcs
gcv
get
s
gh
gl
gla
gsf
i
gsl
h
lpc
lus
rc
Description
Sets the end-of-line sequence:
0: Off
3: LVAL extended by 16 (stat) pixels
7: LVAL shifted by 16 pixels to encompass
stat pixels
Sets whether PRNU coefficients are
enabled or disabled. Where i is:
0 = PRNU coefficients disabled
1 = PRNU coefficients enabled
Returns list of commands sent.
Reads the camera model number.
Reads all of the camera parameters.
Read the camera serial number.
Read the firmware version and FPGA
version.
Returns the value of the parameter
specified.
Returns all of the available ―get‖
commands.
Gets a line of video (without pixel
coefficients applied) displaying one pixel
value after another and the minimum,
maximum, and mean value of the
sampled line.
Read the average of line samples.
Reads the requested Camera Link control
frequency.
1 = EXSYNC frequency
2 = Spare
3 = Direction
Returns the current state of the camera's
LED where:
1 = Red
2 = Green
5 = Blinking green
6 = Blinking red
Display the online help. Refer to the Select
Cable Camera ASCII Command Help for
details.
Loads the previously saved pixel
coefficients from non-volatile memory
Load the settings saved using the lus
command at set specified in sus
command
Resets the entire camera (reboot). Baud
rate is not reset and reboots with the value
last used.