16. If your computer is losing dramatic time or the BIOS configuration reset to default, the
battery has no power.
Caution
1. Do not replace battery yourself. Please contact a qualified technician or your
retail.
2 .The computer is provided with a battery-powered real-time clock circuit. There
is a danger of explosion if battery is incorrectly replaced. Replace only with same
or equivalent type recommended by the manufacture. Discard used batteries
according to the manufacturer's instructions
17. IMPROPER INSTALLATION OF VESA MOUNTING CAN RESULT IN SERIOUS
PERSONAL INJURY! VESA mount installation should be operated by professional technician,
please contact the service technician or your retail if you need this service.
18. CLASSIFICATION:
Supply Class I adapter
No applied part
IPX0
Continuous Operation
Not AP or APG category
19. Disconnect device: Appliance inlet.
20. Follow the national requirement to dispose unit.
21. Maintenance: to properly maintain and clean the surfaces, use only the approved
products or clean with a dry applicator.
22. Contact information:
No.1, Alley 20, Lane 26, Reuiguang Road Neihu District, Taipei,
Taiwan 114, R.O.C.
TEL: +886 2-27927818
23.
24. This equipment shall not be used for life support system.
25. Accessory equipment connected to the analog and digital interfaces must be in
compliance with the respective nationally harmonized IEC standards (i.e. IEC 60950 for data
processing equipment, IEC 60065 for video equipment, IEC 61010-1 for laboratory equipment,
and IEC 60601-1 for medical equipment.) Furthermore all configurations shall comply with the
system standard IEC 60601-1-1. Everybody who connects additional equipment to the signal
input part or signal output part configures a medical system, and is therefore, responsible that
the system complies with the requirements of the system standard IEC 60601-1-1. The unit is
for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment
and IEC 60XXX certified equipment outside of the patient environment. If in doubt, consult the
technical services department or your local representative.
26. User not to contact SIP/SOPs and the patient at the same time.
27. The sound pressure level at the operator's position according to IEC 704-1:1982 is no
more than 70dB (A).
DISCLAIMER
This set of instructions is given according to IEC 704-1. Advantech disclaims
all responsibility for the accuracy of any statements contained herein