Optional Controls

Wall Thermostat

Use only a 750 millivolt DC two-wire circuit ther-
mostat, placed in the same room as the heater,
typically 5' off the floor. Avoid drafty areas or any
area that may affect the accuracy of the thermo-
stat.
The thermostat should be connected to the
stove using a minimum of 16 gauge wire with a
maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the
two left terminals on the terminal block located on
the valve. Do not overtighten the connections. IT IS
NOT NECESSARY TO DISCONNECT ANY OTHER
WIRES. See Fig. 22.
At the thermostat, the two wires should be
connected to the two connection screws on the
thermostat base plate per the manufacturer's
instructions.
For thermostatic operation, the On/Off/T-Stat
switch must be in the T-stat position, and the pilot
light must be on.

Remote Control

When using a remote, the remote receiver should
be wired to the terminal block the same way the
thermostat would be. See the instructions above.
Follow the operating instructions included with
the Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING THE CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER OR DANGER-
OUS OPERATION. ALWAYS VERIFY PROPER
OPERATION AFTER SERVICING THE APPLI-
ANCE.
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
Figure 20. Accessory wiring diagram.
Optional Brick Kit 155888
CAUTION!
THE BRICK PANELS AND LOG PARTS
ARE EXTREMELY FRAGILE. USE BOTH
HANDS TO SUPPORT EACH PIECE AS
YOU HANDLE THEM.
Carefully unpack the panels and identify the parts
by the illustration, fig. 20.
1. Remove the Top Plate. Simply lift it up off of the
2. Remove the Glass Frame. Disengage the two
3. Install the Right Side Panel.
4. Install the Lower Rear Panel.
5. Install the Left Side Panel as you did the right
6. Install the Upper Rear Panel.
ROCKER
SWITCH
ON
Figure 21. Orient the panels as shown here.
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
stove body.
spring latches located at the top of the firebox
and lift the frame up and out through the top.
Position the panel, upper end first, beyond the
exhaust baffle and then against the firebox
wall. Slide it forward against the firebox front.
Orient the panel so that the course of three full
bricks is on top.
side. Be sure to push the panel forward, up
against the firebox front.
Orient the panel with the rounded edge on top.
Set the panel up high and then carefully lower
it to seat its bottom edge against the top of the
lower panel. The side panels will hold it in place.
Upper Rear Panel, 221198
Lower Rear Panel, 221197
Left Side
Panel, 221196
Right Side
Panel, 221195
17