High Altitude Adjustment - Jøtul GF 600 DV II Installation And Operation Instructions Manual

Firelight direct vent gas heater
Table of Contents

Advertisement

REMOVE THE BLACK RUBBER
GASKET FROM THE VALVE!
VARIABLE
REGULATOR TOWER
Figure 19. Regulator parts.
18. Install the Brick Panels, Log Set and Embers as
appropriate. See pages 18-19.
19. Adjust the primary Air Shutter and flame appear-
ance following instructions on page 20.
20. Reassemble the stove, apply gas to the system
and check for leaks using a soapy water solution.

High Altitude Adjustment

The decreased atmospheric pressure of higher
altitudes affects heat value of gaseous fuels. Most
gas suppliers derate the gas intended for use at
elevations above 2000 feet. Check with your gas
supplier before performing derate adjustment to
the burner.
The Jøtul GF 600 DV II may be adjusted for altitude
over 2000 ft. (610 - 1371 m) for natural gas.
Check with your gas supplier and, if necessary,
install High Altitude Adjustment Kit 155808.
DO NOT DERATE FOR PROPANE.
For the U.S:
THE DERATING KIT MUST BE INSTALLED BY AN
AUTHORIZED SERVICE TECHNICIAN IN ACCOR-
DANCE WITH THE MANUFACTURER'S INSTRUC-
TIONS AND ALL CODES AND REQUIREMENTS OF THE
AUTHORITY HAVING JURISDICTION. THE INFORMA-
TION STICKER MUST BE FILLED OUT BY THE IN-
STALLER AND ADHERED TO THE APPLIANCE AT THE
TIME OF THE CONVERSION. THE QUALIFIED SERVICE
AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS DERATING.
For Canada:
This unit has been tested for installation at high
altitudes in accordance with Canadian test stan-
dard CAN/CGA-2.17.
THE DERATING SHALL BE CARRIED OUT IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN1-B-149.1 AND .2 INSTALLATION CODE.
16
Derating Procedure
Follow Steps 1-7 of the Fuel Conversion procedure
on pages 15-16 to change the burner orifice for use
MAIN GAS
with Natural Gas. Use the 3.1 mm orifice supplied
VALVE
with the High Altitude Adjustment Kit. Instructions
are also included.
INSTALLER: Fill out the appropriate information
and apply the high altitude conversion label
provided to the rating plate on the appliance.
THIS STOVE HAS BEEN CONVERTED FOR USE AT
AN ALTITUDE OF: ___________
Orifice Size: __________ Manifold Press. _____
Input Btu/Hr. _________ Fuel Type __________
Date of Conversion ___________
Figure 19. High Altitude Conversion Label.