BLOWER
Plug
Figure 22. Attaching the blower wire harness.
Optional Wall Thermostat or
Remote Control
When installing a wall mounted thermostat to the
Allagash it must be 750 millivolt DC two-wire circuit
thermostat. The thermostat should be placed in the
same room as the heater, typically 5' off the floor.
Avoid drafty areas or any area that may effect the
accuracy of the thermostat.
The thermostat should be connected to the
Allagash using a minimum of 16 gauge wire with a
maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the
two lower terminals on the terminal block located
directly above the ignitor button. Do not overtighten
the connections. IT IS NOT NECESSARY TO DISCON-
NECT ANY OTHER WIRES. See Figure 23.
For the thermostat to work the On/Off/T-Stat
switch on the back of the stove must be in the T-stat
position, and the pilot light must be running, for it is
the power source for the thermostat.
At the thermostat the two wires should be
connected to the two connections screws on the
thermostat base plate per the manufacturer's
instructions.
Remote Control
The remote receiver should be wired to the terminal
block the same as the thermostat. See the instruc-
tions above.
18
Snapstat
(attached to
blower bracket)
HI/LO
SWITCH
Wire Harness
CAUTION:
LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
THE CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. ALWAYS
VERIFY PROPER OPERATION AFTER
SERVICING THE APPLIANCE.
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
Figure 23. Wiring Diagram / Remote or Thermostat
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL