Jøtul GF 200 DV Installation And Operation Instructions Manual

Jøtul GF 200 DV Installation And Operation Instructions Manual

Jotul lillehammer gas heater installation and operation instructions gf 200 dv

Advertisement

GF 200 DV
Lillehammer
Gas Heater
Installation
and
Operation
Instructions
IF THE INFORMATION IN THESE INSTRUC-
TIONS ARE NOT FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SER-
VICE AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL
SWITCHES.
• DO NOT USE THE PHONE IN YOUR
BUILDING. IMMEDIATELY CALL YOUR GAS
SUPPLIER FROM A NEIGHBOR'S PHONE.
• FOLLOW YOUR GAS SUPPLIER'S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS
SUPPLIER, CALL THE FIRE DEPARTMENT.
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES IN-
STRUCTIONS DANS CETTE NOTICE POUR
REDUIRE AU MINIMUM LE RISQUE D'INCENDIE
OU POUR EVITER TOUT DOMMAGE MATERIEL,
TOUTE BLESSURE OU MORTALIT'E.
NE PAS ENTREPOSER NI UTILISER D'ESSENCE
NI OU LIQUIDES INFLAMMABLES DANS LE
VOISINAGE DE CET APPAREIL OU DE TOUT
AUTRE APPAREIL.
L'INSTALLATION LE SERVICE DOIVENT
ETRE EXECUTES PAR UN INSTALLATEUR
QUALIFIE, AGENCE DE SERVICE OU LE
FOURNISSEUR DE GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ.
• NE PAS TENTER D'ALLUMER L'APPAREIL
• NE TOUCHEZ A AUCUN INTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES
SE TROUVANT DANS LE BATIMENT OU VOUS
VOUS TROUVEZ.
• APPELEZ IMMEDIATEMENT VOTRE
FOURNISSEUR DE GAZ CHEZ UN VOISIN.
SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SER-
VICE DES INCENDIES.
WARNING:

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 200 DV

  • Page 1 GF 200 DV Lillehammer Gas Heater Installation Operation Instructions WARNING: IF THE INFORMATION IN THESE INSTRUC- TIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP- ERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY:...
  • Page 2 Welcome to Jøtul... Congratulations on the purchase of your new Jøtul GF 200 DV Lillehammer - a direct vented gas heater especially designed and approved for installation into a variety of configurations where close clearance to combustibles is required. We at Jøtul are glad you’ve made the decision to warm your hearth with a Jøtul product.
  • Page 3: Table Of Contents

    Jøtul GF 200 Lillehammer Direct Vent Gas Heater Manufactured and Distributed by: Jøtul A.S.A. Fredrikstad, Norway Jøtul North America Portland, Maine Test Standards This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton, Wisconsin to ANSI Z21.88-1998 (NFPA 54) and CSA 2.33-M98 for Canada.
  • Page 4: Specifications

    16 1/2” Steady State (A.F.U.E.): 73% Piezo Ignitor / Standing Pilot The Jøtul GF 200 DV Lillihammer is a Direct Vent wall furnace designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using 6 5/ 8"...
  • Page 5: General Information

    Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149. DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.
  • Page 6: Safety Information

    Lillehammer gas stove. • Clothing or other flammable materials should not be placed ON or NEAR the Lillehammer gas stove. Surveiller les enfants. Garder les vetements, les meubles, l’essence ou autres liquides a vapeur inflammables loin de l’appareil.
  • Page 7: Clearance Requirements

    Figure 3. Mantel / Trim Clearances Parallel Installation Max. Alcove Depth 24” 2” (26mm) 1” (26mm) Figure 4. Clearances with stove parallel to the walls 1” (26mm) Alcove Installation Maximum Depth: Minimum Width: Minimum Ceiling Height: Corner Installation 6” or less 2”...
  • Page 8: Venting Requirements

    • IF VENTING SYSTEM IS DISASSEMBLED FOR ANY REASON, REINSTALL PER THE INSTRUCTIONS Vent Restriction The GF 200 DV Lillehammer includes two draft restrictor plates found in the parts bag. These must be installed togethe within the stove in the follow-...
  • Page 9: Vertical Vent Systems

    Vertical Venting Requirements These requirements apply to any installation that includes a verrtical vent run. The GF 200 DV Lillehammer can be vertically vented through a roof or ceiling following these guidelines: Steep roofs, nearby trees, and predominantly windy conditions can contribute to poor draft or down-draft occurances.
  • Page 10: Co-Linear Hearthmount Systems

    Co-linear Hearthmount Installation The Jøtul GF 200 DV Lillehammer may be vented through a masonry fireplace using Simpson Dura- Vent Chimney Liner Conversion Kit 923GK. When installed in the manner described below, this system can improve the performance of the appliance in cold climate situations, as well as simplify the vent installation.
  • Page 11: Vent Height Requirements

    Simpson Dura-Vent Chimney Conversion Kit. (USE KIT #931, #932, or #933) 4. The Exhaust Restrictor plate, shipped with the stove, must be installed according to the instruc- tions on page 8. IMPORTANT NOTICE THE USE OF AN EXISTING CHIMNEY AS AN AIR INTAKE IS NOT COVERED UNDER THE ANSI Z21.88-1999-CSA...
  • Page 12: Horizontal Vent Options

    Simpson Dura-vent (#907B). See Figure 12-1. • The maximum horizontal run made directly off the rear of the stove into a 14” snorkel cap (#982) must be no more than a 24” section of Simpson Dura-vent (#904). See Figure12-3. •...
  • Page 13: Wall Shield Installation

    2. Align the holes in the wall shield with the holes in the rear shroud. 3. Secure the wall shield to the stove with the four 1/4” hex head screws. OPTION # 5 Figure 12-5. Horizontal vent with two elbows.
  • Page 14: Vent Termination Clearances

    Vent Termination Requirements Figure 15. Vent Terminal Clearances - National Fuel Gas Code A = Clearance above grade, veranda, porch , deck, or balcony : *12 inches (30 cm) minimum. B = Clearance to window or door that may be opened: 9 inches (23 cm) minimum.
  • Page 15: Mobile Home Installation

    Mobile Home Installation The Jøtul GF 200 DV Lillehamme can be installed for use in a mobile home in the U.S. and Canada pro- vided: 1. The stove is secured to the floor of the mobile home. Use Jøtul Floor Mounting Kit #154342.
  • Page 16 Front Panel (1) to the side panels (2). (Note: You do not have to remove these bolts.) Pull the Front Panel away from the stove and lift off of Bottom Plate. 4. Release the Glass Retainer Clips (12) on top of the firebox and carefully lift the Glass Panel up and out.
  • Page 17: Gas Connection

    15. Apply the identification labels to locations as follows: • Label A - apply to back of stove. • Label B - apply to stove’s rating plate. • Small Conversion Label - apply to valve. 16. Reassemble the stove. Connect supply gas to the system and check for leaks using a soapy water solution.
  • Page 18: Gas Pressure

    Mix a 50-50 solution of water and dish soap. • Light appliance- see lighting instructions on page 21 of this manual or on the stove’s rating plate. • Brush or spray all joints and connections with the soapy water solution.
  • Page 19: High Altitude Adjustment

    High Altitude Kit. Apply this label to the control valve after it has been converted for high altitude. THIS STOVE HAS BEEN CONVERTED FOR USE AT AN ALTITUDE OF ____________________ Orifice Size _______ Manifold Press: ______ Input BTU/Hr. _____ Fuel Type __________ Date of Conversion ____________________ Figure 21.
  • Page 20: Air Shutter Adjustment

    The log set must be removed from the packaging and arranged in the unit prior to start up of the gas stove. Do not handle the log set with your bare hands. Always wear gloves to prevent skin irritation from the ceramic fibers.
  • Page 21: Thermostat / Remote Control

    DISCONNNECT ANY OTHER WIRES. See Figure 24. For the thermostat to work, the On/Off/T-Stat switch on the back of the stove must be in the T- stat position, and the pilot light must be running, as it is the power source for the thermostat.
  • Page 22: Operation

    If and when a vacuum is used for any service on the stove, ALWAYS be sure the stove is cold and that there are NO hot embers or sparks. 6. Remember, this appliance has a continuous burning pilot flame.
  • Page 23: Maintenance

    Maintenance The GF 200 DV Lillehamer gas stove and its venting system should be inspected before use and at least annually by a qualified service technician. IMPORTANT: ALWAYS TURN OFF THE GAS SUPPLY TO THE STOVE BEFORE ANY SERVICE WORK IS PERFORMED ON THE STOVE.
  • Page 24: Maintenance Record

    Maintenance Record Jøtul GF 200 Lillehammer Model: Direct Vent Stove Serial Number: __________________________ Date of Purchase: _______________________ Dealer: _________________________________ Address: _______________________________ _________________________________ Phone: _________________________________ Type of Fuel: Natural Gas ____ Propane _____ Fuel Conversion? YES _______ NO ________ Installer: ________________________________...
  • Page 25: Parts Illustration

    Illustrated Parts List GF 200 DV Lillehammer Figure 29.
  • Page 26: Replacement Parts List

    Fuel Conversion Kit - NATURAL 129173 Fuel Conversion Kit - PROPANE 129471 129116 Torx T-20 Screwdriver To order replacement parts, contact your local Authorized Jotul Dealer. Parts and specifications are subject to Forest Green Jøtul Iron NOTE: ONLY USE 10390536 10390585 GENUINE JØTUL...
  • Page 27: Lighting Instructions

    • Do not use any phone in your building. 1. STOP! Read the safety information above. 2. Access the lower controls. 3. Turn the stove ON/OFF switch to “OFF”, or set the thermostat to lowest setting (if used). 4. Confirm that the gas supply line shut-off valve is open.
  • Page 28 Stoves and fireplaces must be installed to conform to local and national building regulations. In preparing to install this appliance, it is important that all instructions issued with the unit are carefully read and strictly followed. Jøtul pursues a policy of continual product develop- ment.

This manual is also suitable for:

Gf 200 dv lillehammer

Table of Contents