Horizontal Termination - Jøtul GF 600 DV II Installation And Operation Instructions Manual

Firelight direct vent gas heater
Table of Contents

Advertisement

Horizontal Termination

Minimum vertical rise from the top exit position
is a 24" section vent pipe. See fig. 10.
A horizontal vent run made directly off the rear
of the stove must terminate ONLY with a 36"
Snorkel Cap.
The maximum horizontal run shall include
no more than a single 24" section of pipe.
See figs. 11 and 11a.
A single 45° Elbow may be used to offset
the vent for a corner installation as in fig. 11.
The termination cap must not be recessed into the
wall or siding. Do not fill air space in wall around
termination cap with any type of insulation.
Wall Cut-out: A minimum 10" X 10" square hole
is adequate for proper pipe clearance through a
wall, provided the vent is positioned to maintain
2" minimum clearance at the top. A 1" minimum
clearance must be maintained to combustible
material around the other sides.
Maximum Wall Thickness: 14 in. (356 mm)
Any horizontal run of vent must be level or have
a 1/4" rise for every foot of run toward the
termination cap.
Installation of a Vinyl Siding Standoff is required
to prevent damage to vinyl siding between the
vent cap and the exterior wall.
The horizontal termination cap must maintain a
3" clearance to any overhead combustible
projections that are 2 1/2" or less. It must also
maintain a 12" clearance from projections that
exceed 2 1/2". See fig. 13.
Figure 11. Rear Exit Corner Termination, only into a
36" Snorkel. Maximum horizontal run is 24"
(610 mm) with one 45° Elbow.
Minimum vertical
rise with horizontal
termination: 24"
Figure 10. A vertical run in a horizontal termination
must be at least 2 feet (61 cm).
Fig. 12
Figure 11a. Rear Exit Horizontal Termination, only
into a 36" Snorkel. Maximum horizontal run is 24"
(610 mm ).
Maximum
horizontal with
2 ft. vertical is 16"
90° Elbow
Standard Horizontal
termination cap
Rear Exit
24 "
Position
610 mm
C L
59"
(150 cm)
center line
with required
2ft. rise and
90° elbow
36" Snorkel
Termination