Jøtul Allagash GF3 DVII Installation And Operation Instructions Manual

Direct vent gas heater

Advertisement

Quick Links

Jøtul GF3 DVII
Allagash
Direct Vent
Gas Heater
Installation
and
Operation
Instructions
Warnock Hersey
C
US
IF THE INFORMATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SERVICE
AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL SWITCHES.
• DO NOT USE THE PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER
FROM A NEIGHBOR’S PHONE.
• FOLLOW YOUR GAS SUPPLIER’S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER,
CALL THE FIRE DEPARTMENT.
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUC-
TIONS DANS CETTE NOTICE POUR REDUIRE AU
MINIMUM LE RISQUE D’INCENDIE OU POUR
EVITER TOUT DOMMAGE MATERIEL, TOUTE
BLESSURE OU MORTALIT’E.
NE PAS ENTREPOSER NI UTILISER D’ESSENCE
NI OU LIQUIDES INFLAMMABLES DANS LE
VOISINAGE DE CET APPAREIL OU DE TOUT
AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT ETRE
EXECUTES PAR UN INSTALLATEUR
QUALIFIE, AGENCE DE SERVICE OU LE
FOURNISSEUR DE GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.
• NE PAS TENTER D’ALLUMER L’APPAREIL
• NE TOUCHEZ A AUCUM NTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES SE
TROUVANT DANS LE BATIMENT OU VOUS
VOUS TROUVEZ.
• APPELEZ IMMEDIATEMENT VOTRE
FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ
LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SERVICE
DES INCENDIES.
WARNING:

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul Allagash GF3 DVII

  • Page 1 WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE Jøtul GF3 DVII VICINITY OF THIS OR ANY OTHER APPLIANCE.
  • Page 2 Welcome to Jøtul... Congratulations on the purchase of your new Jøtul GF3 DVII Allagash gas stove. We at Jøtul are happy you’ve made the decision to warm your hearth with a Jøtul product. Your new Allagash benefits from our experience as the world’s largest manufacturer of solid fuel burning appliances for over 140 years.
  • Page 3 Jøtul GF3 DVII Allagash Table of Contents Direct Vent Gas Heater Manufactured and Distributed by: Jøtul A.S.A. Fredrikstad, Norway Jøtul North America Portland, Maine Test Standards Warnock Hersey PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THE APPLIANCE. KEEP THESE INSTRUCTIONS FOR FUTURE USE.
  • Page 4: Specifications

    Specifications...
  • Page 5: General Information

    Standards DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE. General Information Glass Front...
  • Page 6: Safety Information

    Safety Information Location Electrical Hazard Hearth Requirements DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.
  • Page 7: Clearance Requirements

    Clearance Requirements Parallel Installation Alcove Installation Corner Installation Mantel and Trim Clearances...
  • Page 8: Venting Requirements

    Venting Requirements Horizontal Overhang 2 ft. 2 ft. min. min. Lowest Discharge Termination Opening 2 ft. min. Roof Pitch is X / 12 2 ft. = minimum height from roof to lowest discharge opening Vertical Venting Requirements (Vertical Termination) · ·...
  • Page 9 First Restriction Setting OUTER Second Restriction Setting MIDDLE Horizontal Venting Requirements 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3...
  • Page 10 Ã9DS@8UÃW@IUà Co-linear Vent Installation U@SHDI UDPIÃFDUà I9Ã8 QÃDTà S@RVDS@9ÃUPà GGPXÃAS@TCà DSà DIUPÃUC@Ã8CDHI@`à @YC6VTUà B6Tà v…rpyh’Ãyvr…Àˆ†‡Ã S@TCÃ6DSà r‘v†‡Ã‡u…‚ˆtuÇurà r‡v…rÃyrt‡uÂsà ‡urÃpuv€r’à @‘uhˆ†‡Ãsyr‘Ãvƒrà €ˆ†‡Ãr‘‡rqÇurà r‡v…rÃyrt‡uÂsÇurà puv€r’Ãhqà p‚rp‡rqÇ‚ÃhÃqv…rp‡Ã ‰r‡Ã‡r…€vh‡v‚Ã DSÃDIU F@Ãsyr‘à ƒvƒrà €ˆ†‡ÃirÃhà €vv€ˆ€Ã‚sÃ%Ãs‡à #$&Ãp€à à r‘‡rqÃir’‚qÇurà qh€ƒr…Ãh…rhà DS@QG68@à 96H Q@SÃ6S@6à 6Àr‡hyÃiy‚px ‚ssÃyh‡rÀˆ†‡Ã p‚€ƒyr‡ry’Ærhyà ‡urÃpuv€r’Ã...
  • Page 11: Mobile Home Installation

    Simpson Dura-Vent Chimney Wr…‡vphyÃUr…€vh‡v‚Ãà 8hƒÃÆ(( à Conversion Kit I‚‡ÃvpyˆqrqÃvÃxv‡à Tv€ƒ†‚Ã9ˆ…hWr‡Ãà Ur…€vh‡v‚ÃFv‡Ã AÃ"Ã9Wà à 6GG6 6TCà T‡‚‰rÃà Tv€ƒ†‚Ã9ˆ…hWr‡Ã Uuv€iyrÃ6qhƒ‡r…à DpyˆqrqÃvÃxv‡à #Ãvpuà  À€à Ayr‘ÃGvr…à Tv€ƒ†‚Ã9ˆ…hWr‡Ã I‚‡Ãv ÃÆ((Ã(žÃ@yi‚Ãà pyˆqrqÃvÃ I‚‡ÃvpyˆqrqÃvÃxv‡ xv‡à 6ƒƒ…‚ƒ…vh‡rÃyrt‡uÂsà Tv€ƒ†‚Ãà Av…rpyh’à 9ˆ…hWr‡ÃQvƒrÃs‚…à yvr…Â…ÃVGà ‰r…‡vphyÃ…v†rÃà "Ãyv†‡rqà I‚‡ÃvpyˆqrqÃvÃxv‡à ƒ…rshi…v ph‡rqÃpuv€ r’Ãvƒrà )ÃÃ...
  • Page 12: Vent Termination Window

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 Vent Termination 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0...
  • Page 13 Vent Terminal Clearances 6 inches (16 cm) min. *12 inches (30 cm) minimum. 9 inches (23 cm) minimum. within 3 feet (90 cm) 6 feet (1.8 mimimum 12 inches (30 cm) m) minimum. *12 inches (30 cm) minimum. 18 inches (46 cm) minimum.
  • Page 14: Fuel Conversion

    Fuel Conversion Gas Conversion Procedure WARNING: THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECH- NICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AU- THORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE.
  • Page 15 Figure 14. Regulator Tower and gasket. ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE INSIDE BACK COVER OF THIS MANUAL AND ON THE BACK OF THE RATING PLATE. Figure 13. Removing the Pilot Hood and Pilot Orifice.
  • Page 16: Gas Connection

    Gas Connection Gas Pressure A T-HANDLE GAS COCK IS REQUIRED IN MASSACHUSETTS IN COMPLIANCE WITH CODE 248 CMR. Figure 16. Inlet and Manifold pressure test points. Figure 15. Gas supply valve types and fittings.
  • Page 17: High Altitude Adjustment

    Natural Gas 129130 0 - 2000 ft. Propane 1.5 mm 129146 (0 - 610 m) Natural Gas Do Not Derate 2001 - 4500 ft. Propane 754517P (611 - 1370 m) High Altitude Adjustment Figure 17. High Altitude Conversion Label. This sticker is included in all high altitude kits and must be applied to the stove when converted for high altitude .
  • Page 18: Log Set Installation

    Air Shutter & Flame Picture Log Set Installation Adjustment Figure 18. Proper flame picture. WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.
  • Page 19: Optional Blower Installation

    Optional Blower Installation IMPORTANT: IF THE OPTIONAL FORCED BLOWER KIT(PART # 129161) IS TO BE INSTALLED ON THE STOVE AT THE TIME OF THE INSTALLATION OR IN THE FUTURE, THE GAS SUPPLY LINE SHOULD BE INSTALLED AS CLOSE TO THE FLOOR AS POSSIBLE. USE OF A 90° DIRECTLY OFF THE VALVE WILL ALLOW FOR PROPER CLEARANCE FOR THE BLOWER.
  • Page 20 CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE. Figure 22. Attaching the blower wire harness. THERMOPILE ROCKER Optional Wall Thermostat or SWITCH Remote Control STAT...
  • Page 21: System Check

    System Check CAUTION: DO NOT ATTEMPT TO ALTER THE FLAME APPEARANCE BY POSITIONING THE GAS VALVE IN ANY OTHER POSITION OTHER THAN THE FULL “ON” POSITION. 3” - 4” 3” - 4” 1” - 2” 1” (25mm) 3/8” 1/8” (8mm) (3mm) Min.
  • Page 22: Operation

    Operation Maintenance IMPORTANT: BEFORE ANY SERVICE WORK IS PER- FORMED ON THE STOVE, ALWAYS TURN OFF THE GAS SUPPLY TO THE STOVE AND UNPLUG THE BLOWER IF INSTALLED.
  • Page 23 Service Technician__________________ Company Name______________________ Date of service_______________________ Work Performed______________________ __________________________________ Service Technician__________________ Company Name______________________ Date of service_______________________ Work Performed______________________ __________________________________ Service Technician__________________ Service Technician__________________ Company Name______________________ Company Name______________________ Date of service_______________________ Date of service_______________________ Work Performed______________________ Work Performed______________________ __________________________________ __________________________________...
  • Page 24: Illustrated Parts List

    Illustrated Parts List...
  • Page 25 Jøtul GF3 DVII Allagash Parts Cast Iron Parts Matte Black Blue Black Ivory Green Indigo Jøtul Iron Right Door 10390492 10390427 10390429 10390432 10390436 10390485 Left Door 10390392 10390327 10390329 10390332 10390336 10390385 Front Panel 10390192 10390127 10390129 10390132 10390136 10390185 Side Panel 10203292...
  • Page 27: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. LIGHTING INSTRUCTIONS Control Knob TO TURN OFF GAS TO THE APPLIANCE:...
  • Page 28 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul pursues a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.