Fuel Conversion - Jøtul GF 600 DV II Installation And Operation Instructions Manual

Firelight direct vent gas heater
Table of Contents

Advertisement

The appliance and its main gas valve must be
disconnected from the gas supply piping system
during any pressure testing on that system at test
pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas
supply line by closing its individual manual gas
shut-off valve (gas cock) during any pressure testing
of the gas supply piping system that is equal to or
exceeds pressures of 1/2 psig (3.5kPa).
MANIFOLD PRESSURES
NATURAL GAS
PROPANE
DO NOT ALLOW THE INLET GAS
PRESSURE TO EXCEED 13.5" WC
(OR 1/2 PSIG) AS SERIOUS DAMAGE
TO THE VALVE CAN RESULT.

Fuel Conversion

The GF 600 DV II Firelight gas stove is shipped from
the factory equipped to burn NATURAL GAS. Use the
Fuel Conversion Kit included with the stove, to
convert the burner for use with Propane. The kit
contains all the necessary components needed to
complete the task and ensure safe operation,
including labels that must be affixed to the stove.
CAUTION: Before proceeding with this conver-
sion, the gas supply must be shut off prior to
disconnecting the electrical power.
THE CONVERSION KIT IS TO BE INSTALLED BY
AN AUTHORIZED JØTUL SERVICE TECHNICIAN
IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE. THE
QUALIFIED AGENCY PERFORMING THIS WORK
ASSUMES RESPONSIBILITY FOR THIS
CONVERSION.
14
MIN
MAX
1.2 WC
3.8 WC
2.9 WC
11.0 WC
NOTICE:
WARNING:
Conversion Kit (LPG #155893, NG # 155894)
Tools required:
• 1/4" nut driver
• 1/2" & 13 mm open end wrench or deep-well
socket
• Torx T20 or slotted screwdriver
• 7/16" open end wrench
• 3 mm allen wrench
• 4 mm allen wrench
Conversion Kit Contents:
• 1 regulator tower labeled for propane
• 3 regulator tower screws
• 1 burner orifice (3.2 mm for NG, #49 for LP)
• 1 pilot orifice (#51 for NG, #30 for LP)
• Label A - to be completed and applied to the back
of the stove
• Label B - apply to the rating plate
• Small valve label - apply to valve body
• Conversion instructions
IN CANADA:
THE CONVERSION SHALL BE CARRIED
OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL AU-
THORITIES HAVING JURISDICTION AND
IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE CAN1-B149.1 & .2 INSTAL-
LATION CODE.
Fuel Conversion Procedure
1. Turn off gas supply to the stove.
2. Remove the Grille and Top Plate.
3. Release the spring latches atop the firebox and
lift glass assembly up and out of the stove.
4. Remove the Logset and lift out the Rear Wall
Skirt and Burner Skirt, fig. 16.
Rear Wall Skirt
Burner Skirt
Figure 16. Lift the Rear Wall Skirt and Burner Skirts.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents