8-3. Insulation Tests

On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance: 7 M Ω or more with DC 500 V Megohm Tester
Dielectric strength test: AC 4,000 V/1 minute, with no abnormalities ............................. 220 V --- 240 V products

8-4. No-load Current Value

After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
230
Current (A) max.
0.6