Carel MPXPRO User Manual page 58

Electronic controller
Hide thumbs Also See for MPXPRO:
Table of Contents

Advertisement

ENG
Par.
Description
/FF
Assign defrost temperature probe 2 (Sd2) - See /FA
/FG
Assign auxiliary temperature probe 1 (Saux1) - See /FA
/FH
Assign auxiliary temperature probe 2 (Saux2) - See /FA
/FI
Assign ambient temperature probe (SA) - See /FA
/FL
Assign ambient humidity probe (SU) - See /FA
/FM
Assign glass temperature probe (Svt) - See /FA
/Fn
Assign dewpoint value (SdP) to a serial probe
0 = Function disabled
1 = Serial probe S8
2 = Serial probe S9
/c1
Probe 1 calibration
/c2
Probe 2 calibration
/c3
Probe 3 calibration
/c4
Probe 4 calibration
/c5
Probe 5 calibration
/c6
Probe 6 calibration
/c7
Probe 7 calibration
/U6
Maximum value of probe 6
/L6
Minimum value of probe 6
/U7
Maximum value of probe 7
/L7
Minimum value of probe 7
CtL (Control)
OFF
ON/OFF control
0 = ON; 1 = OFF;
St
Set point
St2
Intake probe set point with "Double thermostat"
rd
Set point diff erential St
rd2
Set point diff erential St2 with "Double thermostat"
0.0 = function disabled
r1
Minimum set point
r2
Maximum set point
r3
End defrost signal by timeout
0 = disabled, 1 = enabled
r4
Automatic night-time set point variation
r5
Maximum and minimum temperature monitoring probe
0 = monitoring disabled
1 = control probe (Sreg)
2 = virtual probe (Sv)
3 = outlet probe (Sm)
4 = defrost probe(Sd)
5 = intake probe (Sr)
rt
Duration of the current maximum and minimum temperature monitoring session
rH
Maximum temperature acquired in the session
rL
Minimum temperature acquired in the session
r6
Probe for night-time control
0 = virtual probe Sv; 1 = intake probe Sr
ro
Control off set with probe error
r7
Master solenoid valve confi guration
0 = local valve;1 = network valve (connected to Master)
rSu
Suction valve closure delay in normal regolation mode
CMP (compressor)
c0
Delay enable compressor and evaporator fans on power-up
c1
Minimum time between successive starts
c2
Minimum OFF time
c3
Minimum ON time
c4
ON time for duty setting operation (Toff = 15 minutes fi xed)
0 = compressor/valve always OFF; 100 = compressor/valve always ON
cc
Running time in continuous cycle
c6
Low temperature alarm bypass time after continuous cycle
c7
Defrost priority over continuous cycle 0 = no, 1= yes
MPXPRO - + 0300055EN rel. 1.0 30/08/10
3 = Serial probe S10
4 = Serial probe S11
6 = superheated gas probe (tGS)
7 = saturated evaporation temp. probe (tEu)
8 = auxiliary defrost probe (Sd2)
9 = auxiliary probe (Saux)
10 = auxiliary probe 2 (Saux2)
58
Pag.
Def
Min
Max
UoM
41
0
0
11
-
41
0
0
11
-
41
0
0
11
-
41
0
0
11
-
41
0
0
11
-
41
0
0
11
-
41
0
0
4
-
31
0
-20
20
(°C/°F)
31
0
-20
20
(°C/°F)
31
0
-20
20
(°C/°F)
41
0
-20
20
(°C/°F)
41
0
-20
20
(°C/°F)
41
0
-20
20
(°C/°F/
barg/
RH%)
41
0
-20
20
(°C/°F/
barg/
RH%)
27-41
9.3
/L6
160
barg/
RH%
27-41
-1
-20
/U6
barg/
RH%
41
9.3
/L7
160
barg/
RH%
41
-1.0
-20
/U7
barg/
RH%
44
0
0
1
-
35
50
r1
r2
°C/°F
44
50
r1
r2
°C/°F
35
2
0.1
20
°C/°F
44
0
0
20
°C/°F
44
-50
-50
r2
°C/°F
44
50
r1
50
°C/°F
48
0
0
1
-
35
0
-50
50
°C/°F
46
0
0
10
-
46
-
0
999
hour
46
-
-
-
°C/°F
46
-
-
-
°C/°F
35
0
0
1
-
45
0.0
0.0
20
°C/°F
36
0
0
1
-
47
0
0
999
sec
47
0
0
240
min
47
0
0
15
min
47
0
0
15
min
47
0
0
15
min
47
0
0
100
min
47
1
0
15
hour
47
60
0
240
min
47
0
0
1
-
Type
Icon
A
A
A
A
A
A
A
F
F
F
A
A
A
A
A
A
A
A
A
F
A
F
A
A
A
A
C
A
A
A
A
C
A
C
C
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents