3.3
pOsitiOning and lOCatiOn OF the MaChine
Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other
impurities to enter the machines cooling air flow. Preferably site the machine above floor level;
for example on a suitable carriage unit.
Notes for positioning the machine
•
The surface inclination should not exceed 15 degrees.
•
Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in
front of and behind the machine for cooling air to circulate.
•
Protect the machine against heavy rain and direct sunshine.
The machine should not be operated in the rain as the protection class of the machine,
NOTE!
IP23S, allows for outside preserving and storage only.
Never aim metallic grinding spray/sparks towards the equipment.
NOTE!
3.4
COnneCting CaBles
Always check before use that the interconnecting cable, shielding gas hose, earth return
NOTE!
lead/clamp, and mains cable is in a serviceable condition. Ensure that connectors are correctly
fastened. Lose connectors can impair welding performance and damage connectors.
3.4.1
water cooled system: FastMig KMs as + MsF/MXF + FastCool 10 + arcFeed
GND