L-4 Example of complete entry: 202#025#.
L-5 Enter another # to indicate the end of programming.
L-6 You have now deleted a Service User ID location, and (indirectly) his access
code, allowing you to assign that number to another Service User if you wish.
M. DELETE ALL ACCESS CODES
EXCEPT MASTER AND MANAGER
All codes may be deleted together if you are changing everything because of,
for example, suspected theft of codes. Warning - be sure that you want to do
this, because re-creating codes for all the personnel will be time-consuming at
the pushbuttons.
Required User Level: Master, Manager
M-1 Put the lock into Pushbutton Programming Mode.
M-2 Enter Command 299# to delete all Access and Service User Codes.
M-3 Enter another # to indicate the end of programming.
M-4 You have now deleted all User Access Codes, allowing you to re-assign
Access Codes from 0000{0000} to 9999{9999}, if not used by Master or
Managers.
N. ACTIVATE USER ACCESS CODES
A User Code should be activated if it has been de-activated for a certain time
period - during a user's vacation, for example, or if you created an Access Code
but never assigned it to a user. User Codes that are inactive, but might be needed
some time in the future, should be de-activated rather than deleted.
Required User Level: Master, Manager
N-1 Put the lock into Pushbutton Programming Mode.
N-2 Enter Command 300# to activate a User Code.
N-3 Enter the ID location NNN #, where NNN is the specific User ID location,
023 for example.
N-4 Example of complete entry: 300 #023#.
N-5 Enter another # to indicate the end of programming.
N-6 You have now activated the User Access Code assigned to 023.