Visual Feedback Message Definitions
Condition
Valid pushbutton
pressed
Timeout expired
Valid access
code keyed
Access granted
Access granted
(battery low condition
Access denied
Valid programming
entry
Invalid programming
entry (including
duplicate access code)
Tamper shutdown
beginning
Tamper shutdown state
Tamper shutdown
ending
For EPS2000 only:
Lock is ready when front
lever is depressed
Lock's stored power is
starting to fade
A = 1/10 second; B = Twice; C = Can be observed only when you pump the lock's lever
26
Green LED
Red LED
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
Parameters
Duration
1/10 sec
1 sec; A
1 sec
1/10 sec
1/10 sec
1 sec; A
1 sec
1 sec; A
2 sec
1 sec; C
2 sec; C
1/10 sec
1/10 sec
Rate
Once
Once
Once
1 sec
1 sec
Once; B
Once
Once; B
Once
10 sec
Once
Once
1 sec