Page 2
This document must not be reproduced in any way or otherwise further used without the written consent of Kaba AG. All product names are trademarks of the respective companies. Copyright 2016 Kaba AG. All rights reserved. k1evo820 - 201606...
Installing the cylinder into the mortise lock .................. 17 Programming............................ 18 Initial programming of MRD components...................... 18 Initial programming of LEGIC® and MIFARE components................ 18 Master media ................................ 18 Programming with media ............................ 19 User media .................................. 19 Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Page 4
Configuration and traceback .......................... 32 Reset (INI reset)................................ 32 8.5.1 Reset with master media ........................... 32 8.5.2 Reset with programmer 1460 ........................ 32 8.5.3 Reset using tweezers........................... 33 Opening if battery becomes discharged ...................... 34 Troubleshooting........................... 35 Error analysis ................................. 35 Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
The following documents are available from the sales partners: • Kaba programmer 1460 and Kaba programmer 1364 operating manual • User manual for programming and signals of the Kaba evolo components • Kaba evolo system description • Wireless planning guideline •...
Symbols Symbols with the following meanings are used for hazards (depending on hazard source.) General hazard Hazard from electric shock Risk of explosion Risk to electronic components from electrostatic discharge Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
When used externally, the cylinder must be protected against sustained rainfall using a weather guard. When used in fire protection doors, escape routes or rescue routes, the locally applic- able guidelines and building regulations must be observed. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Do not open, drill through or squash lithium batteries. • Do not burn lithium batteries or expose them to high temperatures. • Do not short circuit lithium batteries. • Do not recharge lithium batteries. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
RFID antenna, a locking unit and an electronic module in the inside knob. The lock can only be actuated if the user key (Kaba smart key) is authorised electron- ically. Access authorisation and the operating state are signalled acoustically.
(chlorine, ammonia). Standards Resistance to fire EN 1634-1: 30 min Durability > 100,000 cycles Cycles Battery life at 20°C Approx. 40,000 cycles Depending on the config- uration 3.4.1 Dimensions ≥0 47.5 Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
This device is in compliance with the provisions of Directive 2011/65/ EC of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Note: Distance (X) must be at least equal to the thickness of the internal fitting. 5. Remove the protection film from the cover of the knob. ð The cylinder has been installed. Continue the installation with Chapter [} 4.2.3] to [} 4.2.6]. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
7. Open the locking tabs securing the socket. 8. Pull out the flat ribbon cable. 9. Remove the screw. 10. Pull the e-module out of the axis. ð The e-module has been removed. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Install the flat ribbon cable in such a way that it cannot be crushed, ripped out or damaged by improper handling. 1. Guide the flat ribbon cable through the adapter. 2. Guide the adapter over the axis. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
1. Guide the e-module over the axis, at the same time directing the positioning pin into the adapter. 2. Tighten the screw. 3. Insert the flat ribbon cable into the socket as shown. 4. Close the locking tabs. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Page 16
12. Tighten the screw. 13. Press the cover against the knob housing. Note: Observe the position of the cover. ð The cover clicks into place. 14. Conduct [} 7.3] a function check. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
Note: Distance (X) must be at least equal to the thickness of the internal fitting. 5. Remove the protection film from the cover of the knob. ð The cylinder has been installed. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Manual programming using master media or the programmer 1460 is described in the document Programming Kaba evolo components. The process for setting up the wireless function is described in the handbook for the relevant system software.
(Delete lost User key in the KEM system software in the whitelist (add CardLink to the blacklist) or delete all User key with the corresponding master and then re-program all User key). Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Programming Operating Manual A/B and B structures A/B- structure Master A B- structure Master B User media Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
Note: If no master medium is held up within 20 seconds, pro- gramming mode ends automat- ically and one long acoustic sig- nal sounds. Table 1: Programming user media with B masters Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Note: If no master medium is held up within 20 seconds, pro- gramming mode ends automat- ically and one long acoustic sig- nal sounds. Table 2: Deleting individual user media Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
Note: If no master medium is held up within 20 seconds, pro- gramming mode ends automat- ically and one long acoustic sig- nal sounds. Table 3: Deleting individual B masters Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
» All B masters under the A mas- 1, 2 1 x long ter will be deleted. 1 x short 10 s Table 5: Deleting all B masters Key: Firmware version 42xx For Mechatronic cylinder Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
Master A Beep A master approx 15 s insert into the cylinder., the INI reset will be carried out after 15 s. 15 s Table 7: INI reset with master media for CardLink Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
1364. The firmware (FW) is updated together with the programmer 1460. A detailed description of programming can be found in the separate operating manual for the programmer 1460 and programmer 1364. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
If an attempt is made to gain access with unauthorised user Beep Beep media, an acoustic¹ signal briefly sounds four times. Beep Key: If the function has been activated using the programmer 1460 or the system software. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
ð The acoustic signal denotes the access authorisation. ð The lock can be actuated. 3. Insert an unauthorised user key into the cylinder. ð An acoustic signal sounds 4 x briefly. ð The lock cannot be actuated. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
For information on replacing the cylinder, see Chapter Removing the knob and e- module [} 4.2.3] and Removing the adapter [} 4.2.4] and then Installing the ad- apter [} 4.2.5] and Installing the e-module and knob [} 4.2.6]. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
3. Carefully press the wireless module against the flat ribbon cable and e-module. 4. Insert the wireless module. 5. Push the cover approx. 1 cm onto the wireless module. 6. Insert the cover into the guide track of the e-module. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
Prevent damage to the pin header and wireless module. Pull off the wireless module with the pin header parallel to the e-module, so that the pin header and wireless module are not damaged. 1. Remove the wireless module. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Loss of data With an INI reset, all previously saved settings and data on the E-module are deleted. NOTICE Before components are returned to Kaba for servicing, always carry out a reset on the components. 8.5.1 Reset with master media See Chapter INI reset with master media for whitelist and CardLink™.
2. Locate both contacts on the e-module. 3. Using the tweezers, short-circuit the INI reset contacts for approx. 3 s. ð Two acoustic signals sound to indicate that the INI reset was successful. Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
5. Open the door using the user key. 6. Replace the battery (or batteries) immediately. ð The locking module closes automatically after the battery (or batteries) is (are) inserted. 7. Check the clock time and adjust if required. Round profile k1evo820 - 201606 Kaba mechatronic cylinder compact...
– Faulty Key – Not the correct technology Master Key cannot be pro- – E-module already programmed – Carry out INI reset for e-module grammed short Key: The actuator subsequently opens Kaba mechatronic cylinder compact k1evo820 - 201606 Round profile...
Need help?
Do you have a question about the 1546-K5 and is the answer not in the manual?
Questions and answers