STATES OF THE LOCK

Factory Mode

The factory mode is one of three primary states of the E-Plex 2000 and the E-Plex
PowerStar 2000. The main characteristics of this state are:
• The E2000/EPS2000 opens only when the 8-digit master combination (1-2-
3-4-5-6-7-8) is keyed in.
• The visual indication for 'access granted' is green LED flashing once. A
high-pitched tone is also generated while the green LED is on.
• The Master User must change the combination to be able to exit the
factory mode, and switch to the access mode.

Access Mode

This mode refers to a lock that is operational for user access, and not in
factory or Programming Mode.

Pushbutton Programming Mode

The lock enters the Pushbutton Programming Mode when the user enters the
master combination or one of the manager combinations, preceded and fol-
lowed by the character '#' (ex: #12345678#). Once the E-Plex 2000 is in the
Pushbutton Programming Mode, the Master/Manager can enter one or more
command sequences. Each command sequence ends with a '#' character that
acts like an < enter > character. At the very end of all sequences of program-
ming commands, enter one more # to remove the lock from the Pushbutton
Programming Mode to return to normal access mode.
SEQUENCE OF OPERATIONS
FOR START-UP PROGRAMMING
What is the recommended sequence of operations?
With the E-Plex 2000/EPS2000 in the factory mode.
• Program the Access Code Length (default length is four digits).
The access code field length can only be changed when the
lock is not activated (when still in the factory mode).
• Change factory Master to your own Master Code (always eight digits) to
place lock in access mode.
Put lock in Pushbutton Programming Mode.
• Program the Unlock time.
• Program the Lock for the Duration of Passage Mode (if desired).
• Program the Lock for Tamper Time Settings.
• Program the Lock for Buzzer Volume.
• Add Access Codes as desired.