General Information - Rinnai Arriva 752 Operation Manual

Fireplace
Hide thumbs Also See for Arriva 752:
Table of Contents

Advertisement

General information

Before operation please read these instructions to get an overview of how to operate,
maintain and service your Rinnai gas fire.
Electrical connection
The Arriva 752 is
fitted with a
1.5 m power cord
and 3-pin plug. The
standard electrical
connection is to the right hand
side of the heater front assembly.
If necessary this can be changed
by your electrician to terminate on
the left.
The connection is either direct
wired or connected to a power
point within the cavity. This must
be connected to a dedicated
earthed power point. The electric
isolation switch must be accessible
after the appliance has been
installed. The heater must not
be located immediately below
a socket outlet (potential fire
hazard).
If the supply cord is damaged, it
must be replaced by a licensed
tradesperson. This must be a
genuine replacement part available
from Rinnai, part number 6765B.
Hearths
A hearth is not necessary, but can
be used for decorative purposes
or protection of sensitive flooring
if required. General guidelines if
installing a hearth.
It must not obscure the front
of the fire
The bottom of the appliance
must be level with the top
of the hearth so there is a
continuous level
Size should be at least the
width and depth of the fire
Installation by a licensed
tradesperson
Ensure your installer talks to
you about the use and care of
this appliance, and that you
understand these instructions. The
installer also needs to complete
the appliance installation checklist
and installer details, and leave this
guide with you.
Positioning the Arriva 752
To gain maximum heating
advantage from the bottom air
discharge, position the Arriva 752
close to the floor.
The unit can be fully recessed as
long as the mantel and surround
clearances on the previous page
are maintained.
Power failure
If the power is disrupted while
the heater is operating, once the
power is restored, the heater will
go into power failure mode—on
the control panel there will be
flashing zeros in the error display,
and the LED will flash green.
To reset the heater, press the On/
Off button on the control panel
twice, or use the remote control
and press the Standby/On button
once (to go on standby) and then
a second time to turn the heater
on.
Safety devices
your Rinnai Arriva 752 is designed
with the following safety devices:
-
flame failure sensing system
-
pressure relief
-
overheat safety switch
-
air temperature sensor
-
thermal fuse
-
overcurrent fuse
-
spark detector
Soot deposits
Small soot deposits inside
the heater or glass is normal.
Significant build up however is not
normal and will require a service
call. Refer to the troubleshooting
section for further information.
TV installation above the
fireplace
If installing a flat
screen television
above the fire,
the main issue is
heat, heat from the
appliance, and heat from the
flueing components that may sit
behind the television (especially if
recessed).
The Arriva 752 has a fan that
distributes warm air at a low level.
This pushes heat out and around
the room as opposed to straight
up, so installation of a television
may be an option. The Arriva 752
also has a power flue that has
virtually zero clearance to any
cavity in which it is installed. The
flueing components are also small
and generate very little heat.
Generally the bottom of the
television recess should be at
least 450 mm above the fire.
Please check with the television
supplier to check clearances. Some
television manufacturers have
warranty conditions that state a
television is not to be installed
above a fireplace.