Axlink Port And Led (4-Pin Captive-Wire) - AMX Enova DVX-2100HD Operation/Reference Manual

6x2 all-in-one presentation switcher
Table of Contents

Advertisement

AxLink Port and LED (4-pin captive-wire)

The AxLink port (FIG. 26) allows the DVX-2100HD to support AMX AxLink devices.
FIG. 26
AxLink Port and LED
The (green) AxLink LED indicates AxLink data activity:



The AxLink port can be used to supply power to downstream AxLink-compatible devices as long as the
maximum current draw is less than 2 Amps. To isolate the DVX-2100HD from high inrush current, AxLink
devices, or potential power faults on the AxLink bus, it is strongly recommended that you power external
AxLink devices from an independent power supply.
Refer to the following table for the wiring length information used with the DVX-2100HD:
Wiring Guidelines
Wire size
18 AWG
20 AWG
22 AWG
24 AWG
FIG. 27 provide wiring requirements for the AxLink connector:
Top view
FIG. 27
Mini-Phoenix connector wiring diagram (direct data and power)
Enova DVX-2100HD 6x2 All-in-One Presentation Switcher Operation/Reference Guide
Off - No power, or the controller is not functioning properly.
1 blink per second - Normal operation.
3 blinks per second - AxLink bus error. Check all AxLink bus connections.
Maximum wiring length
154.83 feet (47.19 meters)
98.30 feet (29.96 meters)
63.40 feet (19.32 meters)
38.68 feet (11.79 meters)
To the Controller's
AxLink/PWR connector
Wiring and Device Connections
To the external AxLink device