Axlink Port And Led (4-Pin Captive-Wire) - AMX Enova DVX-3150HD Operation/Reference Manual

Enova dvx-3150hd/3155hd series 10x4 all-in-one presentation switcher
Hide thumbs Also See for Enova DVX-3150HD:
Table of Contents

Advertisement

Wiring and Device Connections

AxLink Port and LED (4-pin captive-wire)

The AxLink port (FIG. 46) allows the DVX to support AMX AxLink devices.
FIG. 46
AxLink Port and LED
The (green) AxLink LED indicates AxLink data activity:



The AxLink port can be used to supply power to downstream AxLink-compatible devices as long as the
maximum current draw is less than 1 Amp. To isolate the DVX from high inrush current, AxLink devices, or
potential power faults on the AxLink bus, it is strongly recommended that you power external AxLink devices
from an independent power supply.
The AxLink port provides only limited power to connected AxLink devices. It is
recommended to use an alternate power source when connecting AxLink devices to
the DVX.
When using the DVX with the NXA-PDU-1508-8 power distribution unit, do NOT
connect +12V power from any of the NXA-PDU's AxLink ports to the AxLink power
pin.
Refer to the following table for the wiring length information used with the DVX:
Wiring Guidelines
Wire size
18 AWG
20 AWG
22 AWG
24 AWG
FIG. 47 provides wiring requirements for the AxLink connector:
Top view
FIG. 47
Mini-Phoenix connector wiring diagram (direct data and power)
32
Off - No power, or the controller is not functioning properly.
1 blink per second - Normal operation.
3 blinks per second - AxLink bus error. Check all AxLink bus connections.
Maximum wiring length
154.83 feet (47.19 meters)
98.30 feet (29.96 meters)
63.40 feet (19.32 meters)
38.68 feet (11.79 meters)
To the Controller's
AxLink/PWR connector
Enova DVX-3150HD/3155HD All-in-One Presentation Switcher Operation/Reference Guide
To the external AxLink device
Top view